2.1.4 |
Design and Dimensions of the HiPath 3000 Systems |
2.1.4.1 |
Design and Dimensions of HiPath 3800 |
Two configurations |
| Depending on the requirements, HiPath 3800 can be used as: |
| • | a single-cabinet system (basic cabinet BC) |
| • | a two-cabinet system (BC + expansion cabinet EC) |
Design |
| The basic cabinet BC has nine slots and the expansion cabinet EC has thirteen slots for peripheral boards. The common control board CBSAP has a fixed slot (slot 6, only in the BC). |
| Depending on your requirements, up to three LUNA2 power supply units can be used in the basic cabinet BC and up to four in the expansion cabinet EC. |
| The HiPath 3800 has various connection options for connecting the peripherals: |
| • | SIVAPAC connectors are available on the backplane for connecting the external main distribution frame MDFU-E using CABLUs (prefabricated cabling units) or to connect external patch panels. |
| • | Connector panels with RJ45 jacks for connecting the peripheral device directly. The connector panels are clipped onto the SIVAPAC connectors on the backplane. |
| • | For U.S. only: connector panels with CHAMP jack for connecting the peripheral device directly. The connector panels are clipped onto the SIVAPAC connectors on the backplane. |
| • | Connector panels with SIPAC 1 SU connectors for connecting the external main distribution frame MDFU-E or external patch panels using CABLUs. The connector panels are clipped onto the SIVAPAC connectors on the backplane. |
| The type of connection used will be decided in consultation with the customer on conclusion of the agreement. The cabinets will be delivered accordingly with or without clipped-on connector panels. |
Two installation options |
| HiPath 3800 is suitable for installation both as a standalone system and in a 19-inch cabinet. |
Dimensions |
2.1.4.2 |
Design and Dimensions of HiPath 3550 |
Design |
| The housing intended for wall mounting (Figure 2-2) HiPath 3550 contains one shelf with six slot levels. The slot levels (shown in Figure 4-58), numbered in ascending order from the attachment side, have the following assignments: |
| • | Slot levels 1-3: peripheral boards (two slots per level). |
| • | Slot level 4: CBCC control board only. |
| • | Slot level 5: SIPAC slot |
| • | Slot level 6: optional boards (up to 5 modules) |
| The power supply is on the rear panel of the subrack. |
| The connection cables to the peripherals (telephones, trunk connections etc.) can be connected directly. Use an external MDFU in certain situations (CMI). |
Dimensions |
2.1.4.3 |
Design and Dimensions of HiPath 3350 |
|
Design |
| The housing intended for wall mounting (Figure 2-3)HiPath 3350 contains one shelf with three slot levels. The slot levels (shown in Figure 4-61), numbered in ascending order from the attachment side, have the following assignments: |
| • | Slot level 1: peripheral boards (two slots) |
| • | Slot level 2: CBCC control board only. |
| • | Slot level 3: optional boards (up to 5 modules) |
| The power supply is on the rear panel of the subrack. |
| The HiPath 3350 does not need an external main distribution frame. The connection cables to the peripherals (telephones, trunk connections etc.) are directly connected to the boards. |
Dimensions |
2.1.4.4 |
Design and Dimensions of HiPath 3500 |
Design |
| The housing intended for use with 19-inch cabinets (Figure 2-4) HiPath 3500 contains four slot levels with the following assignments (represented in Figure 4-66): |
| • | Slot levels 1-3: slide-in shelves for peripheral boards (2 boards can be plugged in on each level) |
| • | Slot level 4: slide-in shelf for CBRC control board |
| • | Slot level 5: optional boards (up to 3 modules) |
| The power supply is on the rear panel of the subrack. |
| Connection to the peripherals (telephones, trunk connections, etc.) is set up via RJ45 jacks on the board's front panel. |
Dimensions |
2.1.4.5 |
Design and Dimensions of HiPath 3300 |
Design |
| The housing intended for use with 19-inch cabinets (Figure 2-5)HiPath 3300 contains three slots with the following assignments (represented in Figure 4-67): |
| • | Slot level 1: slide-in shelves for two peripheral boards |
| • | Slot level 2: slide-in shelf for CBRC control board |
| • | Slot level 3: optional boards (up to 3 modules) |
| The power supply is on the rear panel of the subrack. |
| Connection to the peripherals (telephones, trunk connections, etc.) is set up via RJ45 jacks on the board's front panel. |
Dimensions |
| HiPath 3000/5000 V9, Service Documentation, Issue 7 | up ![]() |
|
![]() |
||
| Disclaimer & Copyright | ID: P31003H3590S100017620 | 2012-06-25 |