Table 7-2
|
HiPath 3500 as a GW, Procedure for System Installation and Startup
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Refer to the following board descriptions for information:
|
|
•
|
STLS4R - for S0 trunk connection
|
|
•
|
TS2R - for the S2M trunk connection
|
| Note: Analog workpoint clients can be connected to the CBRC's T/R ports in emergencies. This ensures telephone operation via the telecommunications network in the event of IP network failure.
|
|
|
|
| Perform the IP connection over the HG 1500 board, HXGR3.
|
|
|
|
|
|
|
|
|
| Note (for Brazil only): The AC power of the system is internally equipped with transient overvoltage protection up to approx. 2 kV. Since additional lightning protection is prescribed for Brazil, the AC power of the system must be conducted through the outlet strip with overvoltage protection (part number C39334-Z7052-C33). In this way, transient overvoltage protection is guaranteed up to approx. 4 kV.
|
|
|
|
|
|
|
|
|
|
|
|
|
| Conducting customer-specific programming with HiPath 3000/5000 Manager E.
|
| Refer to the HiPath 3000/5000 Manager E Help for information on programming individual features.
|
|
|
|
| Performing a system check
|
|
•
|
The following tests must be performed if telephones are directly connected to the gateway:
|
| |
- |
Checking the telephones Check the time and date display on each telephone. If a display does not appear, either the telephone or the link is defective. Replace the terminal or fix the link. Perform random terminal tests as described in Section 12.4.11 "Testing Telephones" on all telephones.
|
| |
- |
Checking for proper system booting Set up internal and external calls at random to check if the system is functioning properly.
|
|
•
|
Test IP configuration Ping the HG 1500 IP address in the gateway Make random external calls (from IP phones or clients to HiPath 5000)
|
|