12.5.2 |
Manual Error Correction Without HiPath 3000/5000 Manager E |
Manually activating a restart (reset)/reload |
| Pressing the reset button on the central control board of HiPath 3000 |
| • | initiates a Reset (hard restart of the entire system with the current CDB) if the button is pressed for less than 5 seconds. The RUN LED lights up when the Reset button is pressed. |
| • | initiates a Reload if the button is pressed longer than 5 seconds. The RUN LED disappears after approximately 5 seconds as verification that the reload has been initiated. The entire content of the customer database is replaced by its default version. All country and customer-specific settings are lost. |
|
Locking out and releasing boards and ports |
| You can lock out and release ports using the lockout switch located on the board. The lockout prevents renewed seizure after the current connection has finished. It creates |
| • | a port lockout in an outgoing direction on analog trunk boards. |
| • | a port lockout in outgoing and incoming directions on trunk boards. |
| • | a lockout of the entire board for subscriber line modules. |
| HiPath 3000/5000 V9, Service Documentation, Issue 7 | up ![]() |
|
![]() |
||