D.3  

HiPath 3350 Board Power Requirement 
 

 Table D-5   Nominal Output of the HiPath 3350 Power Supply Units
 Power Supply Unit  
 Part Number  
 Max. Nominal Output in W  
 5 V  
 -48 V  
PSUP  
S30122-K5658-M  
 15.0  
 19.2  
UPSC-D  
S30122-K5660-A300  
S30122-K5660-M300  
 20.01  
 53.0  
Powerbox PB3000 with LUNA2  
S30177-U773-X with
S30122-K7686-M1  
 -  
 110  
1Nominal output = 40 W. Due to build-up of heat, not more than 20 W may be withdrawn.
You must check whether the total power requirement of the boards used and the workpoint clients connected exceeds the maximum possible output of the PSUP or the UPSC-D with or without Powerbox PB3000. Section D.7 "Checking Whether the Output of a Power Supply Unit is Sufficient" contains a sample calculation.  

 Table D-6   HiPath 3350 Board Power Requirement
 Board or Component  
 Part Number  
 Net Power Requirement in W  
 5 V  
 -48 V  
BS3/1  
S30807-H5482-X  
 -  
 2.0  
BS3/3  
S30807-H5485-X  
 -  
 3.0  
CBCC (including subboards)  
S30810-Q2935-A301  
 7.0  
 0.5  
GEE12  
S30817-Q951-Axxx  
 0.5  
 -  
GEE16  
S30817-Q951-Axxx  
 0.5  
 -  
GEE50  
S30817-Q951-Axxx  
 0.5  
 -  
HXGS3 (in old systems incl. fan kit)  
S30810-Q2943-X, S30810-Q2943-X1  
 10.0  
 2.8  
IVMP8  
S30122-Q7379-X100  
 2.6  
 0.3  
P DM1  
S30807-Q5692-X100  
 -  
 5.0  
SLAD4  
S30810-H2956-X100  
 2.0  
 1.0  
SLAD8  
S30810-H2956-X200  
 2.0  
 1.0  
SLAD16  
S30810-Q2957-X  
 2.5  
 1.51  
SLU8  
S30817-Q922-A301  
 0.8  
 -  
STLS2  
S30817-Q924-B313  
 0.6  
 -  
STLS4  
S30817-Q924-A313  
 1.0  
 -  
STRB  
S30817-Q932-A  
 0.5  
 -  
TLA2  
S30817-Q923-Bxxx  
 0.1  
 -  
TLA4  
S30817-Q923-Axxx  
 0.2  
 -  
TLA8  
S30817-Q926-Axxx  
 0.4  
 -  
TMGL4  
S30810-Q2918-X  
 4.72  
 0.12  
TMQ4  
S30810-Q2917-X  
 3.8  
 -  
V24/1  
S30807-Q6916-X100  
 0.3  
 -  
4SLA  
S30810-Q2923-X200  
 0.7  
 0.7  
8SLA  
S30810-Q2923-X100  
 1.3  
 1.3  
16SLA  
S30810-Q2923-X  
 2.5  
 2.5  
1For each active (off hook) station, the net resource requirement increases by approximately 1.6W (dependent on the telephone's line length and DC resistance).
2Identified at a traffic flow of 0.8 Erlang