A.2  

Accessing system administration 
 
Users can access system administration by entering a user name (ID) and password (authentication). Depending on the active password concept (refer to Section 12.7.1.3 "Logon With User Name and Password" for more details), the procedure is as follows:

 Table A-1   Starting System Administration (Service)
 Step  
 Input  
 Description  
 1.  
 *95  
Start system administration  
 2.  
 XXXXX  
Enter user name:  
 •   Fixed password concept: User name = 31994
 •   Variable password concept: Individual user name
 3.  
 XXXXX  
Enter password:  
 •   Fixed password concept: Password = 31994
 •   Variable password concept: Individual password
Page 12-113 contains an example of initial system administration via Assistant T after the system is booted.

 Table A-2   Expert Mode Code Groups
 Code Group  
 Function  
 System maintenance expert mode (previously Assistant T)  
 11  
Call detail recording  
 12  
Speed dialing system  
 13  
Account codes  
 14  
Set up station  
 15  
CO call privileges  
 16  
Incoming calls  
 17  
Networking  
 18  
Traffic restriction  
 19  
Displays  
 20  
ISDN parameters  
 21  
Analog CO interface  
 22  
System settings  
 23  
Code  
 24  
Door relay  
 25  
Announcement/Music  
 26  
Relays  
 27  
Sensors (HiPath 3550/HiPath 3350/HiPath 3500/HiPath 3300 only)  
 28  
Edit CDB  
 29  
System details  
 30  
Remote service  
 31  
Call distribution  
 32  
Paging  
 33  
Attendant  
 34  
DISA  
 35  
Least Cost Routing (LCR)  
 36  
HiPath Cordless Office  
 37  
Security  
 51 - 63  
Customer administration (previously Manager TC)  

 Table A-3   Expert Mode Codes
 Code  
 Function  
11  
Call detail recording  
 11  
 1  
   
   
CDR/station (call detail recording at station)  
 11  
 1  
 1  
   
View CDR/station; enter station number  
 11  
 1  
 2  
   
Print CDRS  
 11  
 2  
   
   
CDR per trunk (call detail recording per trunk)  
 11  
 2  
 1  
   
View CDR per trunk; select slot/trunk  
 11  
 2  
 2  
   
Print CDRT  
 11  
 3  
   
   
CDR central (call detail recording central)  
 11  
 3  
 1  
   
Output format: 0 = compressed, 1 = long  
 11  
 3  
 2  
   
Station number format, suppress digits: 0 = no, 1 = yes  
 11  
 3  
 3  
   
Incoming calls: 0 = no, 1 = yes  
 11  
 3  
 4  
   
Call duration 0 = no, 1 = yes  
 11  
 3  
 5  
   
Output MSN: 0 = no, 1 = yes  
 11  
 3  
 6  
   
Call charge display: 1 = Amount, 2 = Pulses  
 11  
 3  
 7  
   
Outgoing without connection: 0 = no, 1 = yes  
 11  
 4  
   
   
Call charge factor  
Enter 0 % to 10000 %  
 11  
 5  
   
   
ISDN factor  
Enter 0 % to 10000 %  
 11  
 6  
   
   
Currency, alphanumeric entry of max. 3 characters (not for U.S.)  
 11  
 7  
   
   
Call log: 0 = no, 1 = yes  
 11  
 8  
   
   
CDRA (call detail recording, attendant), pay phone, station.  
 11  
 9  
   
   
Computing accuracy, decimal digits (0 to 3)  
12  
Speed dialing system  
 12  
 1  
   
   
Speed dial numbers, external station numbers  
000 to 999 (HiPath 3550/HiPath 3500);
000 to 299 (HiPath 3350, HiPath 3300)  
 12  
 2  
   
   
Speed dial names (alphanumeric entries of up to 16 characters), only if speed-dialing numbers have been entered1  
13  
Account Code (ACCT)  
 13  
 1  
   
   
Code entries, list 0 to 999  
 13  
 2  
   
   
Checking procedure 0 = Not checked, 1 = Acc. code list, 2 = Number of digits  
 13  
 3  
   
   
Entry procedure 0 = Optional, 1 = Mandatory  
 13  
 4  
   
   
Code length (1 to 11)  
14  
Set up station  
 14  
 10  
   
   
Copy station data  
 14  
 11  
   
   
Station type  
 14  
 11  
 0  
   
Standard  
 14  
 11  
 1  
   
Fax  
 14  
 11  
 2  
   
PhoneMail (5 digits)  
 14  
 11  
 3  
   
Loudspeaker  
 14  
 11  
 4  
   
Answer Machine  
 14  
 11  
 5  
   
External MOH  
 14  
 11  
 6  
   
P.O.T MW LED  
 14  
 11  
 7  
   
PhoneMail (6 digits)  
 14  
 11  
 8  
   
Door station with pulsed loop  
 14  
 11  
 9  
   
Memo  
 14  
 11  
 10  
   
Modem  
 14  
 12  
   
   
Station names (alphanumeric), up to 16 character1  
 14  
 13  
   
   
Override: 0 = denied, 1 = allowed  
 14  
 14  
   
   
Associated Dialing: 0 = denied, 1 = allowed  
 14  
 15  
   
   
DISA: 0 = denied, 1 = allowed  
 14  
 16  
   
   
Call waiting rejection: 0 = off, 1 = on  
 14  
 17  
   
   
Headset 0 = off, 1 = on  
 14  
 18  
   
   
Call pickup group:  
HiPath 3550/HiPath 3500: Groups 1 to 16, max. 32 stations  
HiPath 3350/HiPath 3300: Groups 1 to 8, max. 8 stations  
 14  
 19  
   
   
Reset station PIN: 0 = Reset to 00000  
 14  
 20  
   
   
Override do not disturb 0 = no, 1 = yes  
 14  
 21  
   
   
Missed Calls List: 0 = no, 1 = yes  
 14  
 22  
   
   
MCID: 0 = denied, 1 = allowed  
 14  
 23  
   
   
Call FWD, external: 0 = denied, 1 = allowed  
 14  
 25  
   
   
Data compression 0 = no, 1 = yes  
 14  
 26  
   
   
Select language:
11 = German  
12 = US English  
13 = French  
14 = Spanish  
15 = English
16 = Italian  
17 = Dutch
18 = Portuguese  
19 = Finnish  
20 = Czech  
21 = Danish  
22 = Swedish  
23 = Norwegian  
24 = Turkish  
25 = Telekom, German  
26 = Polish  
27 = Hungarian  
28 = Russian  
29 = Greek  
30 = Slovenian  
31 = Serbo-Croatian  
32 = Estonian  
33 = Latvian  
34 = Lithuanian  
35 = Chinese  
36 = Slovakian  
37 = Catalonian  
38 = German (2)  
39 = English (2)  
40 = Romanian  
41 = Bulgarian  
42 = Macedonian  
43 = Serbian (cyr.)  
44 = Serbian (lat.)  
 14  
 27  
   
   
Do not Disturb: 0 = off, 1 = on  
 14  
 28  
   
   
Telephone lock intercept: 0 = no, 1 = yes  
 14  
 29  
   
   
Dialing method: 1 = DTMF, 2 = DP  
 14  
 30  
   
   
optiPoint BLF (busy lamp field or BLF), Display: No BLF, one BLF, two BLFs  
 14  
 31  
   
   
Ringback protection per station  
 14  
 32  
   
   
Setup station in internal phonebook: 0 = no, 1 = yes  
 14  
 33  
   
   
Edit tel. number 0 = no, 1 = yes  
 14  
 34  
   
   
Monitoring: 0 = not authorized, 1 = authorized  
 14  
 35  
   
   
Keypad dial: 0 = not authorized, 1 = authorized  
 14  
 36  
   
   
Forwarding CFSS  
 14  
 37  
   
   
Speaker calling  
 14  
 38  
   
   
Bar speaker calling  
15  
CO call privileges  
 15  
 1  
   
   
Direct trunk access day; specify reference station  
Enter new data:  
0 = No trunk access except by system speed-dialing  
1 = Incoming only  
2-7 = Allowed list, Allowed list 1-6  
8-13 = Denied list, Denied list 1-6  
14 = Full access  
 15  
 2  
   
   
Direct trunk access night; specify reference station  
Enter new data:  
0 = No trunk access except by system speed-dialing  
1 = Incoming only  
2-7 = Allowed list, Allowed list 1-6  
8-13 = Denied list, Denied list 1-6
14 = Full access  
 15  
 3  
   
   
Allowed lists  
 15  
 3  
 1  
   
Allowed list 1, 100 entries  
 15  
 3  
 2  
   
Allowed 2, 10 entries  
 15  
 3  
 3  
   
Allowed 3, 10 entries  
 15  
 3  
 4  
   
Allowed 4, 10 entries  
 15  
 3  
 5  
   
Allowed 5, 10 entries  
 15  
 3  
 6  
   
Allowed 6, 10 entries  
 15  
 4  
   
   
Denied lists  
 15  
 4  
 1  
   
Denied list 1, 50 entries  
 15  
 4  
 2  
   
Denied 2, 10 entries  
 15  
 4  
 3  
   
Denied 3, 10 entries  
 15  
 4  
 4  
   
Denied 4, 10 entries  
 15  
 4  
 5  
   
Denied 5, 10 entries  
 15  
 4  
 6  
   
Denied 6, 10 entries  
 15  
 5  
   
   
Number of authorized stations (for verification purposes only)  
 15  
 6  
   
   
Telephone lock  
0 = No trunk access except by system speed-dialing  
1 = Incoming only  
2 - 7 = Allowed lists 1-6 (AL 1 to AL 6)  
8 - 13 = Denied lists 1-6 (DL 1 to DL 6)  
14 = Full access (full)  
 15  
 7  
   
   
Toll restriction, 0 = Digit-by-digit, 1= En-bloc sending  
 15  
 8  
   
   
Switched trunk authorization  
 15  
 9  
   
   
Toll restriction, private  
16  
Incoming calls  
 16  
 10  
   
   
Internal station numbers  
 16  
 10  
 1  
   
Station  
 16  
 10  
 1  
 1  
Boards  
 16  
 10  
 1  
 2  
Change station number  
 16  
 10  
 1  
 3  
Find station number  
 16  
 10  
 2  
   
Groups  
 16  
 11  
   
   
DID numbers; (internal) station number is displayed; enter (new) station number  
 16  
 12  
   
   
Intercept position, day; enter new destination, group or Stn. no., max. 6 digits  
 16  
 13  
   
   
Intercept position, night; enter new destination, group or Stn. no., max. 6 digits  
 16  
 14  
   
   
Intercept criteria  
 16  
 14  
 1  
   
on RNA: 0 = no, 1 = yes  
 16  
 14  
 2  
   
on Busy  
 16  
 14  
 2  
 1  
Intercept 0 = no, 1 = yes  
 16  
 14  
 2  
 2  
Call waiting on busy: 0 = no, 1 = yes  
 16  
 14  
 3  
   
on Invalid, intercept: 0 = no, 1 = yes  
 16  
 14  
 4  
   
on Incomplete, intercept: 0 = no, 1 = yes  
 16  
 14  
 5  
   
on Automatic recall, intercept: 0 = no, 1 = yes  
 16  
 15  
   
   
Hunt/group call  
 16  
 15  
 1  
   
Called station no.; select group and assign destination  
 16  
 15  
 2  
   
Ring type; select group and type:  
1 = Circular hunt group  
2 = Linear hunt group  
3 = Group call  
4 = Group call, no answer  
5 = Basic MULAP  
6 = Executive MULAP  
7 = Group call, call waiting  
 16  
 15  
 3  
   
Group name, select group and enter name (alphanumeric)1  
 16  
 15  
 4  
   
Select host (master)/executive, group, and station (only stations that are not the host (master) telephone in another group)  
 16  
 16  
   
   
Call allocation, day; select slot/trunk and assign station no.  
 16  
 17  
   
   
Call allocation, night; select slot/trunk and assign station no.  
 16  
 18  
   
   
Call forwarding-no answer  
 16  
 18  
 1  
   
Select call destination list and destination index (1 - 4).  
Call destination lists:  
 •   up to and including V1.2 = 70
 •   V3.0 or later =
   -   376 for HiPath 3550, HiPath 3500
   -   70 for all other systems
Select destination (1 - 4), possible entries:  
 •   targeted call number of a station or a group
 •   * = identical to called station
 •   #9 = system search of all stations except for the executive extensions
 •   #201 - #260 = uniform call distribution group 01 to group 60
 •   #301 - #316 = announcement device 01 to 16
 •   an external destination, in other words call numbers in satellites and in the central office
 16  
 18  
 2  
   
Internal calls; select station/group:  
 •   up to and including V1.2 = 70
 •   V3.0 or later =
   -   1 - 376 for HiPath 3550, HiPath 3500
   -   1 - 70 for all other systems
 16  
 18  
 3  
   
External calls, day; select station/group:  
 •   up to and including V1.2 = 1 - 70
 •   V3.0 or later =
   -   1 - 376 for HiPath 3550, HiPath 3500
   -   1 - 70 for all other systems
 16  
 18  
 4  
   
External calls, night; select station/group:  
 •   up to and including V1.2 = 1 - 70
 •   V3.0 or later =
   -   1 - 376 for HiPath 3550, HiPath 3500
   -   1 - 70 for all other systems
 16  
 18  
 5  
   
Number of rings (1 to 15) for station/group  
 16  
 18  
 6  
   
Night bell, location for station/group  
 16  
 18  
 7  
   
Night bell, mode:
1 = Immediate connect, 2 = After timeout  
 16  
 18  
 8  
   
Call forwarding (CF) on busy, 0 = Do not forward call, 1 = Forward call  
 16  
 19  
   
   
Ring cadence: 0 = Ring type 1, 1 = Ring type 2, 2 = Ring type 3  
 16  
 20  
   
   
DTMF DID: 0 = denied, 1 = allowed  
 16  
 21  
   
   
Ringback protection (Brazil): 0 = off, 1 = on  
17  
Networking  
 17  
 11  
   
   
Simplified dialing: 0 = Off, 1 = On  
 17  
 12  
   
   
Assign trunk group; select slot/trunk and assign trunk group  
Route 1-8 (HiPath 3350, HiPath 3300)  
Route 1 - 16 (HiPath 3550/HiPath 3500)  
 17  
 13  
   
   
Overflow route; select route and assign overflow route  
 17  
 14  
   
   
Trunk type CO/CS; select trunk type: 0 = CO, 1 = CS  
 17  
 15  
   
   
Route name, select route and enter name (alphanumeric)1  
 17  
 16  
   
   
Route seizure; Route selection: 0=cyclic, 1= linear  
 17  
 17  
   
   
Rerouting (optimized B channel utilization)  
 17  
 17  
 1  
   
Route optimize active: 0 = No, 1 = If route is known, 2 = Always  
 17  
 17  
 2  
   
Change route: 0 = denied, 1 = allowed  
 17  
 18  
   
   
Central intercept  
 17  
 19  
   
   
Call data routing  
 17  
 19  
 1  
   
Destination system  
 17  
 20  
   
   
Digit repetition; select trunk group: 0 = off, 1 = on  
 17  
 21  
   
   
Path optimization: 0 = no, 1 = yes  
 17  
 22  
   
   
QSig: Voice mail  
 17  
 22  
 1  
   
Callback access number  
 17  
 22  
 2  
   
Callback access name  
 17  
 23  
   
   
QSig: Busy signaling  
 17  
 23  
 1  
   
Stations: 0 = no, 1 = yes  
 17  
 23  
 2  
   
Station number, destination system  
 17  
 23  
 3  
   
System number, destination system  
 17  
 24  
   
   
Station number type: 1 = Internal, 2 = DID, 3 = Internal/DID  
18  
Traffic restriction  
 18  
 1  
   
   
Configure exec./sec. groups; select group, enter:  
1 = Exec. 1, 2 = Exec. 2, 3 = Sec. 1, 4 = Sec. 2  
HiPath 3550/HiPath 3500: Group 1-10  
HiPath 3350/HiPath 3300: Group 1-4  
 18  
 2  
   
   
Hotline  
 18  
 2  
 1  
   
Hotline destinations  
HiPath 3550/HiPath 3500 Destination 1-6  
HiPath 3350/HiPath 3300: Destination 1  
 18  
 2  
 2  
   
Hotline station number  
 18  
 2  
 2  
 1  
Hotline Mode: 0 = Off, 1 = Hotline, 2 = Off-hook alarm after timeout  
 18  
 2  
 2  
 2  
Hotline assignment  
HiPath 3550/HiPath 3500 1-6  
HiPath 3350/HiPath 3300 1  
 18  
 2  
 3  
   
Hotline timeout, 1-99 x s  
 18  
 3  
   
   
ITR groups (internal traffic restriction groups)  
 18  
 3  
 1  
   
Group assignment  
 18  
 3  
 1  
 1  
Station  
 18  
 3  
 1  
 2  
Lines, select slot/line  
 18  
 3  
 1  
 3  
Speed-dialing number assignment  
 18  
 3  
 1  
 3-1  
Minimum speed-dialing group, Select group, 0 to 999  
 18  
 3  
 1  
 3-2  
Maximum speed-dialing group, Select group, 0 to 999  
 18  
 3  
 2  
   
Connection groups  
 18  
 3  
 2  
 1  
Matrix, Select Group: 0 = no, 1 = yes  
19  
Displays  
 19  
 11  
   
   
Text messages: select message no. 0 to 9 and enter a text containing up to 24 characters (alphanumeric)1  
 19  
 12  
   
   
Advisory messages: select message no. 0 to 9 and enter a text containing up to 24 characters (alphanumeric)1  
 19  
 13  
   
   
Enter 4-digit time in the format HHMM (hour minute)  
 19  
 14  
   
   
Enter 6-digit date in the format DDMMYY (day month year)  
 19  
 15  
   
   
Call duration: 0 = off, 1 = on  
 19  
 16  
   
   
Name, Call numbers: 0 = Calling ID only, 1 = Name, 2 = Name and calling ID  
 19  
 17  
   
   
Automatic recall 1 = Caller, 2 = Transferred destination  
 19  
 18  
   
   
Transfer before answer: 1 = Transferred by, 2 = Transferred to  
20  
ISDN parameters  
 20  
 1  
   
   
Call number suppression 0 = off, 1 = on  
 20  
 2  
   
   
System station number - incoming  
 20  
 2  
 1  
   
Station number; select trunk group  
 20  
 2  
 2  
   
National number; select trunk group  
 20  
 2  
 3  
   
International number; select trunk group  
 20  
 2  
 4  
   
Type, outgoing; select trunk group:
0 = Unknown, 1 = Station, 2 = National, 3 = International, 4 = Internal  
 20  
 2  
 5  
   
National prefix (U.S. = 1)  
 20  
 2  
 6  
   
International prefix (U.S. = 011)  
 20  
 3  
   
   
Reference clock  
 20  
 3  
 1  
   
Allowed nos. list; select position (slot and port)  
 20  
 3  
 2  
   
Denied nos. list; select position (slot and port)  
 20  
 4  
   
   
EU parameters (not for U.S.)  
 20  
 4  
 1  
   
S0 port configuration; select slot/port and determine connection type (not for U.S.):  
1 = Automatic  
2 = Euro CO PP  
3 = Euro CO PMP  
4 = Euro bus  
5 = CorNet 1  
6 = CorNet 2  
7 = ECMA-QSIG  
8 = ISO-QSIG  
 20  
 4  
 2  
   
S2M port configuration; select slot/port and determine connection type (not for U.S.):  
1 = Euro CO PP  
2 = CorNet 1  
3 = CorNet 2  
4 = ECMA-QSIG  
5 = ISO-QSIG  
 20  
 4  
 3  
   
S0 bus MSN (for verification purposes only)  
 20  
 4  
 4  
   
Call forwarding PMP  
 20  
 4  
 4  
 1  
Multiple subscriber numbers, select index, 1 to 10  
 20  
 4  
 4  
 2  
MSN trunks, select index, 1 to 10  
 20  
 5  
   
   
US parameters (for U.S. only)  
 20  
 5  
 1  
   
BRI parameter  
 20  
 5  
 1  
 1  
CO/protocol:  
1 = AT&T/NI 1  
2 = AT&T/Custom  
3 = Siemens/NI 1  
4 = NT/NI 1  
 20  
 5  
 1  
 2  
SPID admin, select station, select slot/port  
 20  
 5  
 1  
 3  
CAID admin, stn., select CAID  
 20  
 5  
 1  
 4  
PDID admin, stn., select PDID  
 20  
 5  
 1  
 5  
FIN - for message waiting  
 20  
 5  
 1  
 6  
CACH EKTS, select slot/port: 0 = off, 1 = on  
 20  
 5  
 2  
   
PRI parameters  
 20  
 5  
 2  
 11  
Protocol type:  
11 = AT&T/Custom  
12 = AT&T/NI2  
13 = AT&T/NI2 OSA  
14 = AT&T/4ESS  
15 = Siemens/Custom  
16 = Siemens/Custom OSA  
17 = Siemens/NI2  
18 = Siemens/NI2 OSA  
19 = MCI/DEX600  
20 = MCI/DMS250  
21 = BELL/DMS100  
22 = BELL DMS100 TNS  
23 = Nortel/DMS100  
24 = Nortel DMS100 TNS  
25 = SPRINT/DMS250  
26 = Westinghouse  
27 = FTS/DMS250  
28 = FTS/5ESS  
29 = GENERIC/NI2  
30 = GENERIC/NI2 OSA  
31 = QSIG  
32 = IDA-P  
 20  
 5  
 2  
 12  
Frame/line/encod, select slot  
0 = ESF/B8ZS/Normal  
1 = SF/ZCS/Inverted  
 20  
 5  
 2  
 13  
Inwats parameter  
 20  
 5  
 2  
 13-1  
Direction  
 20  
 5  
 2  
 13-2  
DNIS  
 20  
 5  
 2  
 13-3  
Entrance telephone ring destination  
 20  
 5  
 2  
 14  
Calling service, select trunk group  
11 = NONE  
12 = AT&TSDN-GSDN  
13 = AT&TSDDN  
14 = MCI-VN-VS  
15 = SPRINT-VPN  
16 = WICN-PV  
17 = MEG800-TFM  
18 = MCI 800  
19 = ULTRA-800  
20 = WICN-INWATS  
21 = MEG  
22 = MCI-PRISIM-WATS  
23 = SPR-ULTRA-WATS  
24 = WICN-OUTWATS  
25 = ACCU-SDS  
26 = LDS-WC-TSAA  
27 = INTER-800  
28 = MULTIQUEST  
29 = MCI-900  
30 = SDS56  
31 = SDS64C  
32 = SDS64R  
33 = DMS100-PV  
34 = DMS100-INWATS  
35 = DMS100-OUTWATS  
36 = DMS100-FX  
37 = 5ESS-INWATS  
38 = WATS-MSB  
39 = DMS100-TIE  
40 = NI2-INWATS  
41 = NI2-OUTWATS  
42 = NI2-FX  
43 = NI2-TIE  
44 = NI2-HOTEL  
45 = NI2-SCOCS  
46 = CALL-BY-CALL 1  
47 = CALL-BY-CALL 2  
48 = CALL-BY-CALL 3  
49 = CALL-BY-CALL 4  
50 = WATS-BANDED  
 20  
 5  
 2  
 15  
CBC pool:  
11 = AT&TSDN-GSDN  
12 = AT&TSDDN  
13 = MCI-VN-VS  
14 = SPRINT-VPN  
15 = WICN-PV  
16 = MEG800-TFM  
17 = MCI 800  
18 = ULTRA-800  
19 = WICN-INWATS  
20 = MEG  
21 = MCI-PRISIM-WATS  
22 = SPR-ULTRA-WATS  
23 = WICN-OUTWATS  
24 = ACCU-SDS  
25 = LDS-WC-TSAA  
26 = INTER-800  
27 = MULTIQUEST  
28 = MCI-900  
29 = SDS56  
30 = SDS64C  
31 = SDS64R  
32 = DMS100-PV  
33 = DMS100-INWATS  
34 = DMS100-OUTWATS  
35 = DMS100-FX  
36 = 5ESS-INWATS  
37 = WATS-MSB  
38 = DMS100-TIE  
39 = NI2-INWATS  
40 = NI2-OUTWATS  
41 = NI2-FX  
42 = NI2-TIE  
43 = NI2-HOTEL  
44 = NI2-SCOCS  
 20  
 5  
 2  
 16  
CBC access code  
 20  
 5  
 3  
   
S0 bus MSN, select slot/port  
 20  
 5  
 4  
   
QSig: S0 parameter  
 20  
 6  
   
   
QSIG parameter  
 20  
 6  
 1  
   
System number  
 20  
 6  
 2  
   
Group number  
 20  
 7  
   
   
Keypad dial: 0 = denied, 1 = allowed  
 20  
 8  
   
   
System station number - outgoing  
 20  
 8  
 1  
   
Port number  
 20  
 8  
 2  
   
National number  
 20  
 8  
 3  
   
International number  
 20  
 8  
 4  
   
Suppress station number  
21  
Analog CO interface  
 21  
 1  
   
   
Dialing method; select slot/trunk:  
0 = Automatic,
1 = DTMF,
2 = Dial pulses
3 = MFC-R2,
4 = MFC-R2 with OAD  
 21  
 2  
   
   
Delayed dialing; select trunk group:  
0 = No pause, 1 = 1 s, 2 = 3 s, 3 = 6 s, 4 = 9 s  
 21  
 3  
   
   
Trunk call pause; select trunk group: 1 = 6 s, 2 = 13 s  
 21  
 4  
   
   
Line Length; select slot and trunk: 0 = Short 1 = Long  
 21  
 5  
   
   
Charge data module, select slot/trunk: 0 = off, 1 = on  
 21  
 6  
   
   
Silent reversal: 0 = no, 1 = yes  
 21  
 7  
   
   
Port status: 0 = on, 1 = Off (SW), 2 = Off (HW), 3 = Off (HW, SW)  
 21  
 8  
   
   
Allocated without extension  
22  
System settings  
 22  
 11  
   
   
Music on Hold (MOH): 0= Off, 1 = No ring tone, 2 = Ring tone, 3 = Announcement device 1  
 22  
 12  
   
   
Internal Phonebook: 0 = No, 1 = Internal, 2 = LDAP, 3 = All  
 22  
 13  
   
   
V.24 (RS-232) configuration  
 22  
 13  
 1  
   
Select CB baud rate: 1 = 9600 baud, 2 = 2400 baud, 3 = 19200 baud  
 22  
 13  
 2  
   
Port assignment  
 22  
 13  
 2  
 1  
CSTA/CDRC (call detail recording central), output: 0 = none, 1 = V.24 port, 2 = UPN port, 3 = PC-VPL, 4 = LAN  
 22  
 13  
 2  
 2  
Port for CDRS (call detail recording at station), output: 0 = none, 1 = V.24 port, 2 = UPN port  
 22  
 13  
 2  
 3  
Port for CDRT (call detail recording per trunk), output: 0 = none, 1 = V.24 port, 2 = UPN port  
 22  
 13  
 2  
 4  
Port for CDB printout  
 22  
 13  
 2  
 5  
Port for CDR printout  
 22  
 13  
 2  
 6  
Port for CDRA (call detail recording, attendant); if a pay phone is configured, also see code 11 8), output: 0 = none, 1 = V.24 port, 2 = UPN port  
 22  
 14  
   
   
Call FWD, external  
 22  
 14  
 1  
   
Connect call: 0 = On answer, 1 = Immediately.  
 22  
 14  
 2  
   
Call forwarding: 0 = deactivate, 1 = activate  
 22  
 15  
   
   
Caller list mode: 1 = Only external, 2 = External and Internal, 3 = External ring/call  
 22  
 16  
   
   
Applications  
 22  
 16  
 1  
   
Call distribution: 0 = no, 1 = yes  
 22  
 17  
   
   
Tones  
 22  
 17  
 1  
   
Conference, Warning tone: 0 = off, 1 = on  
 22  
 17  
 2  
   
Call pickup, Warning tone: 0 = off, 1 = on  
 22  
 18  
   
   
Transfer key (Retrieve): 1 = Press once, 2 = Press twice  
 22  
 19  
   
   
Class of service  
 22  
 19  
 1  
   
Night answer, Pos. 1-5; enter station  
 22  
 19  
 2  
   
Central telephone lock  
 22  
 20  
   
   
DTMF automatic: 0= no, 1 = yes  
 22  
 21  
   
   
Key click: 0=Off, 1= Volume 1 ... 4 = Volume 4  
 22  
 22  
   
   
DTMF - Pulse/Pause: 1 = 70/70 msec, 2 = 80/80 msec, 3 = 80/250 msec, 4 = 200/200 msec  
 22  
 23  
   
   
Phone lock destination  
 22  
 24  
   
   
Stn. relocate: 0 = denied, 1 = allowed  
 22  
 25  
   
   
Trunk reservation: 0 = off, 1 = on  
 22  
 26  
   
   
Speaking volume: 0 = default, 1 = high  
 22  
 27  
   
   
CO features (Transfer/Conference/Drop): 0 = disabled, 1 = enabled  
 22  
 28  
   
   
Feature Identification Number (FIN) for Transfer (for U.S. only)  
 22  
 29  
   
   
Feature Identification Number (FIN) for Conference (for U.S. only)  
 22  
 30  
   
   
Feature Identification Number (FIN) for Drop (for U.S. only)  
 22  
 31  
   
   
MSN default: 0 = off, 1 = on  
 22  
 32  
   
   
DTMF hidden: 0 = off, 1 = on  
 22  
 33  
   
   
Announcement with connection: 0 = denied, 1 = allowed  
 22  
 34  
   
   
MFC-R2 parameters  
 22  
 34  
 1  
   
Ringback protection  
 22  
 34  
 2  
   
DID digits  
 22  
 35  
   
   
Common hold  
 22  
 35  
 1  
   
By hanging up  
 22  
 35  
 2  
   
Without hanging up  
 22  
 36  
   
   
Switch line, DSS: 0 = no, 1 = yes
(Status 1 = U.S., Status 0 = Rest of World (ROW)  
 22  
 37  
   
   
Advisory call 0 = off, 1 = on  
 22  
 38  
   
   
Trace stop facility  
 22  
 38  
 1  
   
Stop trace  
 22  
 38  
 1  
 01  
Assistant: 0 = inactive, 1 = active  
 22  
 38  
 1  
 09  
HW: 0 = inactive, 1 = active  
 22  
 38  
 1  
 12  
Processor: 0 = inactive, 1 = active  
 22  
 38  
 1  
 15  
APSXF: 0 = inactive, 1 = active  
 22  
 38  
 1  
 16  
General: 0 = inactive, 1 = active
(error 19 cannot be set to inactive)  
 22  
 38  
 1  
 20  
CP: 0 = inactive, 1 = active  
 22  
 38  
 1  
 21  
DH: 0 = inactive, 1 = active  
 22  
 38  
 1  
 23  
Network: 0 = inactive, 1 = active  
 22  
 38  
 1  
 26  
Presence 0 = inactive, 1 = active  
 22  
 38  
 1  
 28  
Recovery: 0 = inactive, 1 = active  
 22  
 38  
 1  
 29  
IO Process: 0 = inactive, 1 = active  
 22  
 38  
 1  
 30  
LW: 0 = inactive, 1 = active (0 to n)  
 22  
 38  
 1  
 11  
LW date: 0 = inactive, 1 = active (41 to n)  
 22  
 38  
 2  
   
Reset 1 = Delete all, 2 = System default  
 22  
 39  
   
   
IP access  
 22  
 39  
 1  
   
IP interface, mode:  
0 = Inactive  
1 = HIP Forwarding  
2 = LIM  
3 = SLIP Routing  
 22  
 39  
 2  
   
IP address, data (7 ... 15): x.x.x.x (x = 0 ... 255)  
Use either "*" or "." as a separator.  
 22  
 39  
 3  
   
Subnet mask  
 22  
 39  
 4  
   
Gateway IP address  
 22  
 40  
   
   
Open numbering  
 22  
 40  
 1  
   
Active/inactive  
 22  
 40  
 2  
   
Voice mail node number  
 22  
 40  
 3  
   
Node number  
 22  
 41  
   
   
UCD permanently available: 0 = inactive, 1 = active  
23  
Code  
 23  
 1  
   
   
Substitute code *, code 75  
 23  
 2  
   
   
Substitute code #, code 76  
 23  
 3  
   
   
Trunk access code; select slot and trunk and enter new code  
 23  
 4  
   
   
Route code; Select route followed by position 1-10 for code and enter new code  
Route 1-8 (HiPath 3350HiPath 3300, )  
Route 1 - 16 (HiPath 3550/HiPath 3500)  
 23  
 5  
   
   
Attendant code  
 23  
 5  
 1  
   
Attendant code DID  
 23  
 5  
 2  
   
Attendant code internal  
 23  
 6  
   
   
Second trunk access code  
 23  
 7  
   
   
Reset telephone lock code  
 23  
 8  
   
   
Hotel terminal  
24  
Door relay  
 24  
 1  
   
   
Entrance phone; select door, max. 6 digits, door 1-4  
 24  
 2  
   
   
Destination; select door, max. 6 digits, door 1-4  
 24  
 3  
   
   
Door opener; select door: 0 = not available, 1 = available, 2 = available with DTMF, doors 1-4  
 24  
 4  
   
   
Call forwarding, door, external; select door: 0 = do not run, 1 = run  
 24  
 5  
   
   
Door opener, DTMF, select station: 0 = denied, 1 = allowed  
25  
Announcement/Music  
 25  
 1  
   
   
Announcement devices  
 25  
 1  
 1  
   
In system (select announcement device 1 ... 16)  
 25  
 1  
 2  
   
Via server (select announcement device 1 ... 16)  
 25  
 2  
   
   
Type of ann., select ann. device: 1 = Ann. type, 2 = Music on hold, 3 = Internal music  
 25  
 3  
   
   
Announcement prior to answer; select slot and trunk  
 25  
 4  
   
   
External MOH  
(Only enter analog line module stations.)  
26  
Relays  
 26  
 1  
   
   
Type; select relay 1 to 4 and assign function:  
11 = Manual on and off  
12 = Off after timeout  
13 = Door opener  
14 = Speaker amplifier (starting contact for amplifier)  
15 = Busy display  
16 = Music on hold  
17 = Call charge pulse  
18 = Second bell  
19 = Station active  
20 = Announcement  
 26  
 2  
   
   
Switching time  
Select relay 1 through 4 and enter up to 3 digits (0 to 255)  
 26  
 3  
   
   
Assigned station  
Select relay 1 through 4 and enter stations or groups
(up to 5 digits)  
 26  
 4  
   
   
Relay name; select relay 1 to 4, enter a name containing up 16 characters (alphanumeric)1  
27  
Sensors (HiPath 3550/HiPath 3350/HiPath 3500/HiPath 3300 only)  
 27  
 1  
   
   
Sensor type: 0 = Alarm, 1 = Call distribution  
 27  
 2  
   
   
Destination station no.; select sensor 1 - 4  
External station with seizure code (trunk/direction)  
Internal station with station prefix (if programmed)  
 27  
 3  
   
   
Station no. for announ.; select sensor 1 - 4 and enter station or group number (max. 6 digits)  
 27  
 4  
   
   
Infobox control data; select sensor 1 - 4 and enter control characters 0 - 9, *, #, max. 24 digits  
 27  
 5  
   
   
Call duration; select sensor 1 through 4 and enter 1 to 255  
 27  
 6  
   
   
Call pause; select sensor 1 through 4 and enter 0 to 255  
 27  
 7  
   
   
Number of rings; select sensor 1 through 4 and enter 1 to 255  
 27  
 8  
   
   
Block time; select sensor 1 through 4 and enter 0 to 255  
 27  
 9  
   
   
Sensor text; select sensor 1 to 4, enter text containing up 16 characters (alphanumeric)1  
28  
Edit CDB  
 28  
 1  
   
   
Print CDB data  
 28  
 2  
   
   
Save CDB data  
 28  
 2  
 1  
   
CDB to MMC  
 28  
 2  
 2  
   
CDB from MMC  
29  
System details  
 29  
 1  
   
   
System  
 29  
 1  
 1  
   
System type (for verification purposes only)  
 29  
 1  
 2  
   
SWversion (for verification purposes only)  
 29  
 2  
   
   
Status display  
 29  
 2  
 1  
   
Call forwarding, external, 0 = Off, 1 = On (for verification purposes only)  
 29  
 2  
 2  
   
Night service, 0 = Off, 1 = On (for verification purposes only)  
 29  
 2  
 3  
   
Trunk, 0 = Inactive, 1 = Active (for verification purposes only)  
 29  
 2  
 4  
   
Ping, 1 = IP address, 2 = Start  
 29  
 2  
 5  
   
MAC address  
 29  
 3  
   
   
Options (HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 only)  
 29  
 3  
 1  
   
Type per option (for review only)  
1 = Relays  
2 = Call detail recording  
3 = Fax/DID  
4 = ANI  
5 = Announcement (Beyer)  
 29  
 3  
 2  
   
Software version for each option (1 to 16) (for verification purposes only)  
 29  
 3  
 3  
   
Reset options  
 29  
 4  
   
   
Boards  
 29  
 4  
 1  
   
Board type, select slot:  
11 = TMS2  
12 = TMST1 - digital  
13 = TIEL  
14 = TMDID  
15 = TML8W  
16 = TMOM  
17 = TMGL8  
18 = TLA2  
19 = TLA4  
20 = TLA8  
21 = TS2N  
22 = TMGL2  
23 = TMGL4  
24 = TMQ2  
25 = TMQ4  
26 = TST1 - digital  
27 = STMD  
28 = STLS2  
29 = STLS4  
30 = SLA16  
31 = SLMO8  
32 = SLMO24  
33 = SLMC8 (CMI V1)  
34 = 4SLA / SLAD4  
35 = 8SLA / SLAD8  
XX = DIUT2  
 29  
 4  
 1  
   
Board type, select slot:  
36 = 16SLA  
37 = SLU8  
38 = ILAN  
39 = SLC16 (CMI V2.2M)  
42 = SLMO8K  
43 = SLMO24K  
44 = SLA8N  
45 = SLA16N  
46 = SLA24N  
47 = TMAMF  
48 = CR8  
49 = SLU4 (Octopus E 10)  
50 = SLU2 (Octopus E 10)  
52 = HXGS (HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300)  
53 = IVMS8  
54 = IVML8  
55 = IVML24  
56 = SLAS16  
57 = TMCAS  
58 = SLUC8 (UP0/E interfaces on CBCC, CBRC, CBCP)  
59 = SLUC4 (UP0/E interfaces on SBSCO)  
60 = SLUC2 (UP0/E interfaces on SBSCS)  
61 = SLAS4N  
62 = SLAS8N  
63 = IVMP8  
64 =  
65 = HXGS3  
66 = SLC16N  
67 = STMD2  
68 = STLS2N  
69 = STLS4N  
70 = SLMO2  
 29  
 4  
 1  
   
Board type, select slot:  
71 = TMEW2  
72 = DIUN2  
73 = SLMA8  
74 = SLMA3  
75 = SLMA2  
76 = SLMO8_HP4K  
77 = STMD3  
78 = SLCN  
79 = STMI2  
80 = IVMN8  
81 = IVMNL  
82 = TM2LP  
83 = TMDID_HP4K  
84 = TMC16  
85 = DIU2U  
86 = EVM2  
87 = TS2N  
88 = STMD3 (feeding)  
 29  
 4  
 2  
 xx  
Reset board (for board no., see 29-4-1)  
 29  
 4  
 3  
 0-9  
Board status  
 29  
 4  
 4  
   
Disable/enable board  
 29  
 5  
   
   
Country initialization  
 29  
 5  
 1  
   
Variable password  
 29  
 5  
 1  
 00 to 99  
See Select country code  
 29  
 5  
 2  
   
Fixed password  
 29  
 5  
 2  
 00 to 99  
Select country code  
11 = Germany  
12 = Netherlands  
13 = France  
14 = Finland  
15 = United Kingdom  
16 = Italy  
17 = Spain  
18 = Portugal  
19 = Switzerland  
20 = Austria  
21 = International  
22 = Ireland  
23 = Belgium  
24 = Brazil  
25 = South Africa  
26 = China  
28 = India  
29 = Czech Republic  
30 = Denmark  
31 = Australia  
32 = Argentina  
33 = Philippines  
35 = Brazil 2  
36 = Singapore  
37 = Hungary  
38 = Malaysia  
40 = Indonesia  
41 = Russia  
42 = Thailand  
46 = Poland  
47 = Greece  
49 = Sweden  
50 = Norway  
51 = Turkey  
52 = U.S.  
53 = Pakistan  
54 = Hong Kong  
55 = New Zealand  
56 = Taiwan  
57 = Korea  
 29  
 6  
   
   
Virtual subscribers  
 29  
 6  
 1  
   
Configure stations  
 29  
 6  
 2  
   
Display stations  
30  
Remote service  
 30  
 1  
   
   
DTMF access: 0 = No access, 1 = Access as host (primary), 2 = Access as client (secondary), 3 = Host and client (primary and secondary)  
 30  
 2  
   
   
ISDN trunk access: 0 = Enable procedure, 1 = Logon (DID) without PIN, 2 = Logon (DID) with PIN, 3 = Callback  
 30  
 3  
   
   
Other access: 0 = Enable procedure, 1 = Logon without code, 2 = Logon (DID) with code, 3 = Callback  
 30  
 4  
   
   
Reset password  
 30  
 5  
   
   
Integrated modem  
 30  
 5  
 1  
   
Station number, remote service, max. 6 digits  
 30  
 5  
 2  
   
DID number, remote service  
 30  
 5  
 3  
   
CAID admin (for U.S. only)  
 30  
 6  
   
   
Digital modem  
 30  
 6  
 1  
   
Station number, remote service, max. 6 digits  
 30  
 6  
 2  
   
DID number, remote service  
 30  
 6  
 3  
   
CAID admin (for U.S. only)  
 30  
 7  
   
   
Callback connection  
 30  
 7  
 1  
   
Destination; select position (1-6)  
 30  
 7  
 2  
   
Password; select position (1-6)  
 30  
 7  
 3  
   
X.75 protocol: 0 = no, 1 = yes  
 30  
 8  
   
   
Automatic CDB printout: 0 = no, 1 = yes  
 30  
 9  
   
   
USBS D channel access  
 30  
 9  
 1  
   
Station number, remote service  
 30  
 9  
 2  
   
DID number, remote service  
31  
Call distribution  
 31  
 1  
   
   
Group assignment; select group ID  
 31  
 2  
   
   
Group parameters  
 31  
 2  
 1  
   
Announcement device; select group  
HiPath 3550/HiPath 3350/HiPath 3500/HiPath 3300: Announcement device 1-4  
 31  
 2  
 2  
   
Wait times; select group, time: 1-9 x 30s  
 31  
 2  
 3  
   
Call cycles  
 31  
 2  
 3  
 1  
Primary cycles; select group  
 31  
 2  
 3  
 2  
Secondary cycles; select group  
 31  
 2  
 4  
   
AICC connection; select group 0 = off, 1 = on  
 31  
 2  
 5  
   
Max. waiting calls; select group  
 31  
 3  
   
   
Wrap-up time: 0 = no wrap-up time, 1-20 = wrap-up x 30s  
 31  
 4  
   
   
Call priority external; select slot/trunk  
 31  
 5  
   
   
Call priority internal  
32  
Paging  
 32  
 1  
   
   
PSE port (slot and trunk)  
 32  
 3  
   
   
Protocol: 1 = ESPA 4.4.5, 2 = ESPA 4.4.3  
 32  
 4  
   
   
Operating mode  
 32  
 4  
 1  
   
Mode urgent  
 32  
 4  
 2  
   
Mode normal  
 32  
 4  
 3  
   
Mode text  
 32  
 5  
   
   
Display  
 32  
 5  
 1  
   
Call number  
 32  
 5  
 1  
 1  
Number of digits  
 32  
 5  
 1  
 2  
Display, filler: 0=none, 1=left, 2=right  
 32  
 5  
 1  
 3  
Filler  
 32  
 5  
 2  
   
Text  
 32  
 5  
 2  
 1  
Number of digits  
 32  
 5  
 2  
 2  
Display, filler: 0=none, 1=left, 2=right  
 32  
 5  
 2  
 3  
Filler  
 32  
 6  
   
   
PSE data transfer; select sequence: 1 = Operating mode, 2 = Call no., 3 = Text  
 32  
 7  
   
   
PSE dial assignment; select station (not for U.S.)  
 32  
 8  
   
   
PSE dial numbers; select index  
33  
Attendant  
 33  
 1  
   
   
Queued calls  
 33  
 3  
   
   
Speed extending: 0 = denied, 1 = allowed  
 33  
 4  
   
   
Extend undialed lines : 0 = denied, 1 = allowed  
34  
DISA  
 34  
 1  
   
   
Day/night. select slot / line: 0 = None, 1 = Only night, 2 = Only day, 3 = Day and night  
 34  
 2  
   
   
DID number  
 34  
 3  
   
   
Security mode: 0 = by time, 1 = by #  
 34  
 4  
   
   
CAID admin (for U.S. only)  
35  
Least Cost Routing (LCR)  
 35  
 1  
   
   
LCR on or off: 0 = off, 1 = on  
 35  
 2  
   
   
Digit transmission: 0 = Digit-by-digit, 1= En-bloc sending  
 35  
 3  
   
   
Dial rule  
 35  
 3  
 1  
   
Name; select line  
 35  
 3  
 2  
   
Format; select line  
 35  
 3  
 3  
   
Type, select line: 0 = undefined, 1 = Main network supplier, 2 = 1-level, 3 = 2-level, 4 = CN, 5 = DICS, 6 = PRI  
 35  
 4  
   
   
Authorization code; select index (1-16)  
 35  
 5  
   
   
Schedule  
 35  
 5  
 1  
   
Time limit; select day index (1 = Monday to 7 = Sunday) and time format (hhmm)  
 35  
 5  
 2  
   
Timezone; select day index (1 = Monday to 7 = Sunday) and time period 1-8  
 35  
 6  
   
   
Class of service (1 to 15); select station  
 35  
 7  
   
   
Route tables  
 35  
 7  
 1  
   
Route; select table/line  
 35  
 7  
 2  
   
Assign dial rule; select table/line  
 35  
 7  
 3  
   
Min. authorization; select table/line  
 35  
 7  
 4  
   
Assign timezone; select table/line  
 35  
 7  
 5  
   
Warning, select table/line: 1 = none, 2 = display, 3 = tone, 4 = display and tone  
 35  
 8  
   
   
Dial plan  
 35  
 8  
 1  
   
Dialed digits; select line  
 35  
 8  
 2  
   
Assign route table; select line  
 35  
 8  
 3  
   
Account codes: 0 = no, 1 = yes  
 35  
 8  
 4  
   
Toll restriction, private: 0 = no, 1 = yes  
 35  
 8  
 5  
   
Toll restriction: 0 = no, 1 = yes  
 35  
 8  
 6  
   
Emergency number  
36  
HiPath Cordless Office  
 36  
 1  
   
   
Log on CMI unit; select device: 1 = inactive  
 36  
 2  
   
   
CMI code; select device  
 36  
 3  
   
   
CMI number; select device, changes not possible  
 36  
 4  
   
   
Reset cordless code  
 36  
 5  
   
   
DECT identification, data:  
1. E/ARC  
2. EIC  
3. FPN  
4. FPS  
37  
Security  
 37  
1  
 
 
Change password  
   
51 - 63  
Customer administration (previously Manager TC)  
 52  
 
 
 
Time, hour/minute  
 53  
 
 
 
Date, ddmmyy  
 55  
 
 
 
Station names  
 56  
 
 
 
Text messages  
 57  
 
 
 
Advisory messages  
 58  
 
 
 
Select language  
 59  
 
 
 
Group names  
 61  
 
 
 
Hotline  
 61  
1  
 
 
Hotline destinations  
 61  
2  
 
 
Hotline station  
 61  
2  
1  
 
Hotline mode, 0 = Off, 1 = Hotline, 2 = Code blue  
 61  
2  
2  
 
Hotline assignment  
 61  
3  
 
 
Hotline timeout  
 62  
 
 
 
Codes, remote service  
 63  
 
 
 
Codes, Cordless  
The "bolded" messages only appear on workpoints that support alphanumeric character entry.1  
1Alphanumeric characters can only be entered at the following workpoints: optiPoint 600 office (in UP0/E mode), optiPoint 410 advance, optiPoint 420 advance and OpenStage 40/60/80.