9.2.1  

Hardware Upgrade 
 
The following hardware requirements apply to HiPath 3000/5000 V5.0 and higher.

Control boards  
If the control board necessary for operating HiPath 3000/5000 V5.0 and higher is not available, a replacement must be performed.

System  
Control board necessary for HiPath 3000/5000 V5.0 and higher  
HiPath 3800  
CBSAP (S30810-Q2314-X and higher)  
HiPath 3550  
HiPath 3350  
CBCC (S30810-Q2935-A401, S30810-Q2935-A301)  
HiPath 3500  
HiPath 3300  
CBRC (S30810-Q2935-Z401, S30810-Q2935-Z301)  
Note for upgrading from hardware < version 1.2:  
If the following subboards are present, they must be replaced: IMODN (replaces the IMOD), MMC (replaces the FMC), CMA/CMS (replaces the CGM/CGMC).  
For Deutsche Telekom AG only: The CBCP board S30810-Q2935-B201 must be replaced by a CBCC board S30810-Q2935-A301.  

Multimedia card MMC  
For the operation of HiPath 3000/5000 V9, an MMC with minimum 128 MB is required.

HG 1500 boards  
The HG 1500 boards listed in the following table are necessary for using the HG 1500 functionality with HiPath 3000/5000 V5.0 and higher. Unnamed HG 1500 boards must be replaced.

System  
HG 1500 board required for HiPath 3000/5000 V5.0 and higher  
HiPath 3800  
STMI2 (S30810-Q2316-X100)  
HiPath 3550  
HiPath 3350  
HXGS3 (S30810-Q2943-X, S30810-Q2943-X1)  
HiPath 3500  
HiPath 3300  
HXGS3 (S30810-K2943-Z1)  
HiPath 3500  
HiPath 3300  
HXGR3 (S30810-K2943-Z)