9.3.3  

Cordless | Multi-SLC 
 


Settings | Cordless | Multi-SLC
 
The parameters for the SLC16 table are configured via Multi-SLC. All SLC16 cards that are in the DECT system are configured, i.e., all SLC16 cards (SLC16 No.) of the individual nodes (Node ID).

Read from CDB, Multi CDB  
The list box Read from CDB contains the names of all opened CDB files of the corresponding communication systems.
With the additional entry Multi-CDB, the SLC16 table data from all open CDB files is merged. Identical data lines in multiple CDBs are displayed only once. In individual CDB's, data lines that differ or that are additional are specially represented, in addition to the corresponding CDB name in the column "Special features", which can't be edited, or with the number of CDB files, if not all have the same data lines. Multi-CDB thus also serves to support the recognition of inconsistencies in the SLC16 tables among several CDB files. For example, lines that have the same SLC number but different RNR numbers are inconsistent. To create consistency, one of the lines with the same SLC number is to be decided on as the reference for all CDB's (corrected, if necessary), the rest of the lines with this SLC number are to be deleted using the context menu and the table is to be saved in all opened CDB files.

9.3.3.1  

SLC16 table 
The data of the CDB file currently displayed in the list field are in the SLC16 table.

SLC16 no.  
SLC16 card number  
System ID  
If a HiPath 3000 system belongs to a HiPath 5000 RSM networking, its Node ID is greater than zero (Network -> HiPath 5000 RSM/AllServe Parameter -> Node -> Node ID). In this case, the System ID of the SLC board of the HiPath 3000 system (Cordless -> Multi-SLC -> SystemID) must be the same one like the Node ID.  
Number  
Number is the call number under which the SLC-16 DSS-1 port (home card) can be reached by other SLC's (current location card). The data are important in order that the individual SLC cards be able to serve a station from external SLC16 cards (current location card).
Specialities  
For Multi-CDB, the respective CDB names are displayed.  

Write into CDB, Multi-CDB  
Write into CDB contains the names of all opened CDB files of the affected communication systems.
The CDB file that is currently displayed/selected in this list is always the one that is written to. This allows the SLC16 table data of one CDB file to be transferred into another one.
In case of Multi CDB, the displayed table data is written to all opened CDB files, thus creating uniformity among these files.

See also:  
   -   Section 9.3.1 "Cordless | System-wide"
   -   Section 9.3.2 "Cordless | SLC"
   -   Section 9.3.4 "Cordless | Base station"