9.19.32  

Maintenance | OpenStage Phones: SW distribution 
 
SW distribution enables the software of individual or several selected terminals and extenders of the OpenStage family to be updated at a preconfigured time.
To access the dialog box, click the SW distribution button in the OpenStage Phones tab.
Before carrying out the software upgrade for the OpenStage terminals, the new software version must be made available by using File | Transfer | SW Transfer and File| Transfer | Communication | APS Transfer.  
The Read Data button is used to read in, and display in the table, the data of the OpenStage terminals and extenders for which a new software version was made available. OpenStage terminals and extenders for which the software is to be updated manually must be selected here.
The time at which to update the software (immediately, time-controlled, or after the next reset) is selected using APS -Activation. Whether Auto Upgrade is activated in the customer database is displayed here for information, as this setting affects the software distribution. If Auto Upgrade is activated, an automatic software update will be done for the selected OpenStage terminals and extenders at the preconfigured time. Manual software updating is done using the Upgrade button.
The data of the OpenStage terminals and extenders selected in the table can be stored using the Store Data button. The LogFile button can be used to query a log file in which all executed actions are recorded.

9.19.32.1  

Phone family area 
The OpenStage terminals visible in the table can be selected here. A manual software upgrade can be executed only for the visible terminals. An automatic software upgrade is, however, not affected by this setting.

9.19.32.2  

Actual version in MMC area 
This displays the current software versions for OpenStage terminals and extenders that are stored on the MMC of the system

9.19.32.3  

APS-Activation area 
The software update for the OpenStage terminals is executed as soon as the corresponding resource is available. The switchover time that follows that is determined by the following setting:
 •   Date/Time:
The terminals are updated at a specified time. The date and time are set from the drop-down lists.
 •   Immediate:
The terminals are updated immediately, as soon as the required system resources are available.
 •   on next reset:
The terminals are updated during the next reset.
Auto Upgrade displays whether the software upgrade will be automatic. For automatic software updating the Automatic OpenStage TDM telephone software update flag has to be activated in Settings | System Parameters | Flags.

9.19.32.4  

Table 
Here the data of the selected OpenStage terminals and extenders read in from the Read Data button can be displayed and the OpenStage terminals and extenders selected for manual or automatic software update.

Call Number column  
Here the number assigned to the terminal is displayed.

Name column  
The name assigned to the station is entered here.

Type column  
Here the type of the terminals or extenders is displayed.

Column: Current SW Version  
Here the current software version of the terminal or extender is displayed.

Upgrade SW Version column  
Here the new software version of the terminal or extender is displayed.

Status column  
Here the following status values for terminals or extenders can be displayed:

Status  
Meaning  
OOS  
OUT_OF_SERVICE:
The terminal or extender is not active.  
NPOSS  
NOT_POSSIBLE:
There is no software in the system for this family of terminals.  
REQ  
REQUIRED:
An update is required but there is no update request.
The Auto Update flag is deactivated.  
MARKED  
MARKED:
The terminal or extender will be upgraded as soon as the system has the required resource available.  
TRANS  
TRANSFERING:
A software transfer is in progress.  
WAIT  
WAITING:
The terminal or extender is currently waiting for further processing by the system  
OK  
OK:
The terminal or extender is at the same or later version as the system.
No further activities.  
FAIL  
FAILED:
The update of the terminal or extender was not successful.
No further activities.  

Column: HW Version  
Here the hardware version of the terminal or extender is displayed.

Column: Access  
Here the slot location of the corresponding terminal or extender is displayed.

9.19.32.5  

Buttons 

Select all  
This button selects all the terminals and extenders listed in the table.

Deselect all  
This button deselects all the terminals and extenders listed in the table.

Read data  
This button is used to read in the data for the selected terminals and extenders and display it in the table.

Store data  
This button is used to store the data of the terminals and extenders that are selected in the table.

Log File  
This button creates a log file in which all executed actions are recorded.

Upgrade  
This button is used to carry out the manual software upgrade of the terminals or extenders selected in the table at the preconfigured time (APS activation).

See also:  
   -   Section 9.19.1 "Transfer | Communication"
   -   Section 9.19.31 "Maintenance | OpenStage Phones: Event Log"
   -   Section 9.19.33 "Maintenance | OpenStage Phones: Trace"
   -   Section 9.19.40 "Transfer | SW Transfer"
   -   Section 10.2.5 "Terminal hw sw version"
   -   Section 10.8.1 "Flags"