9.19.12  

Maintenance | Card status 
 
Card status can be used to display the status of all cards. The status is updated every 3 seconds.

9.19.12.1  

Card status table 

Slot column  
Physical slot number.

Board column  
Card designation.

Not plugged column  
Marked with a cross if the card is not plugged.

Faulty column  
Marked with a cross if the card is faulty (not loaded).

Blocked column  
Marked with a cross if at least one port on this card is blocked.

Free column  
Marked with a cross if all ports on this card are free.

Res. column  
Marked with a cross if at least one station or line on this card has picked up, is being called or is talking.

Clock ref. column  
Marked with a cross if the card is furnishing the clock.

9.19.12.2  

Buttons 

Start, Stop  
Click the Start button to start the display and Stop to end the refresh process.
   -   The status "Blocked" can occur in combination with "Free" or "Res.".
   -   The status "Clock ref." also occurs in combination with other statuses.
   -   The status "Not plugged" or "Faulty" cannot occur in combination with other statuses.
   -   If a plugged card is not displayed, that means that the card is either faulty or cannot be configured.