15.3 |
Configuration Notes |
Configuration of HiPath 5000 RSM |
| The following entry must be made in the vsrv.ini file before starting the Feature server service: |
| [Global] RSA=1 |
Configuration of a standby system |
| When configuring a standby system (HiPath ComScendo Service or HiPath 3000) for the feature HiPath ComScendo Service Resilience, you must follow the procedure below: |
| 1. | Perform country initialization. The system is bootstrapped. Previously saved data, such as, system speed dialing destinations and classes of service are deleted or reset to the basic settings (default). |
| 2. | Execute the licensing procedure. HiPath ComScendo licenses are required for both the "regular" stations and the resilience stations. |
| 3. | Configure IP stations and resilience stations. |
| 4. | Delete the internal station numbers, DID numbers, and names of all resilience stations. |
Configuration of a home system |
| A resilience destination (= IP address of the standby system) must be defined for all resilience stations in the home system (HiPath 3000/5000 Manager E - Stationview - Workpoint Client). |
Configuration of IP workpoint clients (resilience stations) |
| Enter settings for the devices via the Web interface: |
| 1. | Enter the second gateway with the same number under "Administration/System/Gateway Settings". |
| 2. | Select "SRSR enabled" and "Automatic Switch back" under "Administration/System/SRSR Settings". Change the parameters "Switch to home expiry timeout", "Switch to standby expiry timeout", and "TC_TEST expiry timeout" from the default value of 20 to "5". |
| HiPath 3000/5000 V9, Feature Description, Issue 10 | up ![]() |
|
![]() |
||