10.5.4  

optiPoint 500 key modules and adapters power supply 
 
Power is generally supplied to optiPoint 500 telephones by the system via the UP0/E interfaces. When certain optiPoint 500 key modules and adapters are used, the power supply from the system is not adequate.
Table 10-8 indicates which optiPoint 500 key modules require an additional external power supply. In this case, the local power supply units described in Section 10.8.1.1 "Local Power Supply for optiPoint 500, optiPoint 600 office" are used.

 Table 10-8   Additional External Power Supply for optiPoint 500 Key Modules and Adapters
 optiPoint 500 key modules  
 optiPoint 500 Adapters  
 Is an additional external power supply required?  
 Plug-in power supply unit connection  
optiPoint key module  
 generally not required1  
 series-connected2  
optiPoint BLF  
 required  
 connected directly3  
optiPoint analog adapter  
 required  
 series-connected2  
optiPoint ISDN adapter  
 generally not required1  
 series-connected2  
optiPoint phone adapter  
 generally not required1  
 series-connected2  
optiPoint acoustic adapter  
 required4  
 series-connected2  
optiPoint recorder adapter  
 generally not required1  
 series-connected2  
1It is assumed that only one key module or adapter is implemented on each optiPoint 500 telephone. An additional external power supply may be required if several key modules and adapters are implemented on an optiPoint 500 telephone or the maximum UP0/E interface range is reached by the optiPoint 500 telephone. The telephone test described in Section 12.2.11 "Testing Telephones" will establish whether or not additional power is required from a local power supply.
2The local power supply is series-connected to the optiPoint 500 telephone: the "digital" RJ6 jack on the local power supply must be connected to the optiPoint 500 telephone. The other RJ6 jack must be connected to the UP0/E interface on the system.
3The local power supply is connected directly to the optiPoint BLF: one of the two RJ6 jacks on the local power supply unit must be connected with the center jack (indicated by the symbol of a power supply unit) on the optiPoint BLF. A local power supply can supply a maximum of two optiPoint BLFs.
4An additional external power supply is required if the floating contacts on the optiPoint acoustic adapters are being used.