4.1.6  

Connecting the Cable to the Backplane 
 
All cables that leave the system cabinet must be attached to the metal back panel using cable ties.  

Connection options  
Peripheral devices can be connected up to the HiPath 3800 in a number of different ways:
 •   SIVAPAC connector on the backplane for connecting the external main distribution frame via CABLUs (prefabricated cabling units) or for connecting external patch panels (see Section 4.1.6.4 "Connecting Peripherals to the SIVAPAC Connector on the Backplane").
 •   Connector panels with RJ45 jacks for direct connection of peripherals (see Section 4.1.6.5 "Connecting Peripherals to the Connector Panels with RJ45 Jacks"). The connector panels are clipped onto the SIVAPAC connectors on the backplane.
 •   For U.S. Only: Connector panels with CHAMP jack for direct connection of peripherals (see Section 4.1.6.6 "Connecting Peripherals to the Connector Panels with CHAMP Jack (for U.S. only)"). The connector panels are clipped onto the SIVAPAC connectors on the backplane.
 •   Connector panels each with two SIPAC 1 SU connectors for connecting the external mail distribution frame MDFU-E or external patch panels using CABLUs (see Section 4.1.6.7 "Connecting Peripherals to Connector Panels with SIPAC 1 SU Connectors"). The connector panels are clipped onto the SIVAPAC connectors on the backplane.
The type of connection used will be decided in consultation with the customer on conclusion of the agreement. The cabinets will be delivered accordingly with or without clipped-on connector panels.
Danger  
Be sure to connect the main protective earthing terminal on all system cabinets to the grounding point of the electrical building installation before connecting up the peripherals (for example, potential equalization bus).  
The system may only be started (connected to the power supply) if all system cabinets are sealed at the rear with the connection and filler panels provided.  

4.1.6.1  

Backplane of the Basic Cabinet 
 Figure 4-28   HiPath 3800 - Backplane (S30804-Q5392-X) of the Basic Cabinet
 
 Figure 4-29   HiPath 3800 - Connectors and Jacks on the Backplane of the Basic Cabinet
 

 Table 4-6   HiPath 3800 - Assignment of Connectors and Jacks on the Backplane of the Basic Cabinet
 Connector  
 Function  
 X101 - X105  
SIVAPAC connector for connecting peripherals:  
CABLUs and open-end cables are used for connection to the MDFU-E or to an external patch panel (see Section 4.1.6.4 "Connecting Peripherals to the SIVAPAC Connector on the Backplane").  
Note: The SIVAPAC connectors can have the following connector panels:  
 •   Connector panels with RJ45 jacks for direct connection of peripherals (see Section 4.1.6.5 "Connecting Peripherals to the Connector Panels with RJ45 Jacks").
 •   For U.S. only: Connector panels with CHAMP jack for direct connection of peripherals (see Section 4.1.6.6 "Connecting Peripherals to the Connector Panels with CHAMP Jack (for U.S. only)").
 •   Connector panels each with two SIPAC 1 SU connectors for connecting an external main distribution frame or external patch panel using CABLUs (see Section 4.1.6.7 "Connecting Peripherals to Connector Panels with SIPAC 1 SU Connectors").
For selected countries only: PBXXX board: An APPCU adapter (S30807-K5415-X) is used to connect the CAS cable and the DIUN2 connection cable.  
 X109 - X112  
 X116  
SIVAPAC connectors for picking up the signals from the REALS board.  
CABLUs for connection to the MDFU-E (jumper strip for 25 TW):  
 •   C39195-A7267-A372: 3 m in length, short stripped length for MDFU-E slots 11-21 (see Figure 4-36)
 •   C39195-A7267-A373: 3 m in length, long stripped length for MDFU-E slots 1-10 (see Figure 4-36)
Open-end cable (24 TW) for connection to an external patch panel:  
 •   S30267-Z196-A150: 15 m in length
 •   S30267-Z196-A250: 25 m in length
 •   S30267-Z196-A350: 35 m in length
 •   S30267-Z196-A550: 55 m in length
 •   S30267-Z196-A950: 95 m in length
 X201  
68-pin DB68 mini-jack for connecting the cable C39195-Z7611-A10 to the expansion cabinet (for the DBSAP board)  
 X209  
DC port  
 X211, X212  
AC power  
 X214  
10-pin connection for the ring voltage generator RGMOD (for selected countries only)  

4.1.6.2  

Expansion Cabinet Backplane 
 Figure 4-30   HiPath 3800 - Expansion Cabinet Backplane (S30804-Q5393-X)
 
 Figure 4-31   HiPath 3800 - Connectors and Jacks on the Backplane of the Expansion Cabinet
 

 Table 4-7   HiPath 3800 - Assignment of Connectors and Jacks on the Backplane of the Expansion Cabinet
 Connector  
 Function  
 X101 - X106  
SIVAPAC connector for connecting peripherals:  
CABLUs and open-end cables are used for connection to the MDFU-E or to an external patch panel (see Section 4.1.6.4 "Connecting Peripherals to the SIVAPAC Connector on the Backplane").  
Note: The SIVAPAC connectors can have the following connector panels:  
 •   Connector panels with RJ45 jacks for direct connection of peripherals (see Section 4.1.6.5 "Connecting Peripherals to the Connector Panels with RJ45 Jacks").
 •   For U.S. only: Connector panels with CHAMP jack for direct connection of peripherals (see Section 4.1.6.6 "Connecting Peripherals to the Connector Panels with CHAMP Jack (for U.S. only)").
 •   Connector panels each with two SIPAC 1 SU connectors for connecting an external main distribution frame or external patch panel using CABLUs (see Section 4.1.6.7 "Connecting Peripherals to Connector Panels with SIPAC 1 SU Connectors").
For selected countries only: PBXXX board: An APPCU adapter (S30807-K5415-X) is used to connect the CAS cable and the DIUN2 connection cable.  
 X109 - X115  
 X209  
DC port  
 X211  
AC power  
 X214  
10-pin connection for the ring voltage generator RGMOD (for selected countries only)  
 X220 - X223  
Connections for plugging in the DBSAP board.  
DBSAP has a 68-pin DB68 mini-jack for connecting the cable C39195-Z7611-10 to the basic cabinet (to the jack X201).  

4.1.6.3  

Connecting Cables Between the Basic and Expansion Cabinet 
The connection cable C39195-Z7611-A10 has to be connected up for feeding the HDLC, PCM, and clock signals from the basic cabinet to the expansion cabinet:
 •   Basic cabinet = X201 jack
 •   Expansion cabinet = DBSAP board
To ensure smooth operation, use only shielded cables with a maximum length of 1 m.  

4.1.6.4  

Connecting Peripherals to the SIVAPAC Connector on the Backplane 
The boards should be installed in the cabinets as described in Section 4.1.5 "Installing Boards (Configuration Notes)".
Danger  
Be sure to connect the main protective earthing terminal on all system cabinets to the grounding point of the electrical building installation before connecting up the peripherals (for example, potential equalization bus).  
The system may only be started (connected to the power supply) if all system cabinets are sealed at the rear with the connection and filler panels provided.  
Use the CABLUs (prefabricated cabling units) that are listed in the following table to establish the connection with the MDFU-E. Open-end cables must be used if an external patch panel is being used. See also Section 4.1.7 "Using an External Main Distribution Frame or External Patch Panel".

CABLUs and open-end cables for SIVAPAC connectors  

 If  
 Then  
 Slot with  
 SLCN  
 SLMA8  
 SLMO8  
 STMD3  
 TM2LP  
 TMC161  
 TMDID2  
CABLUs for connection between backplane (SIVAPAC connector) and MDFU-E (splitting strip for 16 TW):  
 •   C39195-A7267-A370: 3 m in length, short stripped length for MDFU-E slots 11-21 (see Figure 4-36)
 •   C39195-A7267-A371: 3 m in length, long stripped length for MDFU-E slots 1-10 (see Figure 4-36)
CABLU for connection between backplane (SIVAPAC connectors) and external patch panel S30807-K6143-X (SIVAPAC socket terminal strip):  
 •   S30267-Z333-A20: 2 m in length (refer to Figure 4-42)
 •   S30267-Z333-A50: 5 m in length (refer to Figure 4-42)
Open-end cable (24 TW) for connection between backplane (SIVAPAC connector) and external patch panel:  
 •   S30267-Z196-A150: 15 m in length
 •   S30267-Z196-A250: 25 m in length
 •   S30267-Z196-A350: 35 m in length
 •   S30267-Z196-A550: 55 m in length
 •   S30267-Z196-A950: 95 m in length
 Slot with  
 SLMA  
 SLMA21  
 SLMO2  
CABLUs for connection between backplane (SIVAPAC connector) and MDFU-E (jumper strip for 25 TW):  
 •   C39195-A7267-A372: 3 m in length, short stripped length for MDFU-E slots 11-21 (see Figure 4-36)
 •   C39195-A7267-A373: 3 m in length, long stripped length for MDFU-E slots 1-10 (see Figure 4-36)
CABLU for connection between backplane (SIVAPAC connectors) and external patch panel S30807-K6143-X (SIVAPAC socket terminal strip):  
 •   S30267-Z333-A20: 2 m in length (refer to Figure 4-42)
 •   S30267-Z333-A50: 5 m in length (refer to Figure 4-42)
Open-end cable (24 TW) for connection between backplane (SIVAPAC connector) and external patch panel:  
 •   S30267-Z196-A150: 15 m in length
 •   S30267-Z196-A250: 25 m in length
 •   S30267-Z196-A350: 35 m in length
 •   S30267-Z196-A550: 55 m in length
 •   S30267-Z196-A950: 95 m in length
 Slot with  
 PBXXX1  
A CAS cable is connected via an APPCU adapter (S30807-K5415-X).  
1for selected countries only
2for U.S. only
Information on cable and connector assignment is provided in the board descriptions in Chapter 3 "Boards for HiPath 3000".

Closing the backplane of the system cabinets  
After the cable has been connected, the backplane of the basic cabinet and that of the expansion cabinet (if applicable) must be closed with the dummy panels provided (C39165-A7075-C44).  
 Figure 4-32   HiPath 3800 - Backplane of the Basic Cabinet with Mounted Filler Panels
 

4.1.6.5  

Connecting Peripherals to the Connector Panels with RJ45 Jacks 
The boards should be installed in the cabinets as described in Section 4.1.5 "Installing Boards (Configuration Notes)". The connector panels plugged into the SIVAPAC connectors of the backplane are equipped with eight or 24 RJ45 jacks according to the relevant board.
 Figure 4-33   HiPath 3800 - connector panels with RJ45 Jacks
 
Danger  
Be sure to connect the main protective earthing terminal on all system cabinets to the grounding point of the electrical building installation before connecting up the peripherals (for example, potential equalization bus).  
The system may only be started (connected to the power supply) if all system cabinets are sealed at the rear with the connection and filler panels provided.  
Connect the peripheral directly to the 8-pin RJ45 jacks on the connector panels.

 If  
 Then  
 Slot with  
 STMD3  
Connector panel with eight RJ45 jacks: S30807-Q6624-X  
The RJ45 jacks are configured with four wires. S0 stations can be directly connected (1:1 cable). The receive and send lines should be switched for trunk connections.  
 Slot with  
 SLCN  
 SLMA  
 SLMA21  
 SLMA8  
 SLMO2  
 SLMO8  
 TM2LP  
 TMC161  
 TMDID2  
Connector panel with 24 RJ45 jacks: S30807-Q6622-X  
The RJ45 jacks are configured with two wires.  
 different or no assignment  
The backplane sections of other boards and empty board slots must be covered with filler panels.  
1for selected countries only
2for U.S. only
Information on cable and connector assignment is provided in the board descriptions in Chapter 3 "Boards for HiPath 3000".

4.1.6.6  

Connecting Peripherals to the Connector Panels with CHAMP Jack (for U.S. only) 
The boards should be installed in the cabinets as described in Section 4.1.5 "Installing Boards (Configuration Notes)". The S30807-Q6626-X connector panels attached to the SIVAPAC connectors on the backplane are equipped with a CHAMP jack.
 Figure 4-34   HiPath 3800 - Connector Panel with CHAMP Jack (for U.S. only)
 
Danger  
Be sure to connect the main protective earthing terminal on all system cabinets to the grounding point of the electrical building installation before connecting up the peripherals (for example, potential equalization bus).  
The system may only be started (connected to the power supply) if all system cabinets are sealed at the rear with the connection and filler panels provided.  
Connect the peripheral directly to the CHAMP jack in the connector panels.

 If  
 Then  
 Slot with peripheral card  
A cable with CHAP jack should be used to connect to a main distributor frame or external patch panel.  
 No assignment  
The backplane sections with empty board slots must be covered with filler panels.  
Information on cable and connector assignment is provided in the board descriptions in Chapter 3 "Boards for HiPath 3000".

4.1.6.7  

Connecting Peripherals to Connector Panels with SIPAC 1 SU Connectors 
The boards should be installed in the cabinets as described in Section 4.1.5 "Installing Boards (Configuration Notes)". The S30807-Q6631-X connector panels attached to the SIVAPAC connectors on the backplane have two SIPAC 1 SU connectors each.
 Figure 4-35   HiPath 3800 - Connector Panel with Two SIPAC 1 SU Connectors (S30807-Q6631-X)
 
Danger  
Be sure to connect the main protective earthing terminal on all system cabinets to the grounding point of the electrical building installation before connecting up the peripherals (for example, potential equalization bus).  
The system may only be started (connected to the power supply) if all system cabinets are sealed at the rear with the connection and filler panels provided.  
Use the CABLUs that are listed in the following table to establish the connection with the MDFU-E or an external patch panel. See also Section 4.1.7 "Using an External Main Distribution Frame or External Patch Panel".
In special cases where the prefabricated CABLUs cannot be used, open-end cables should be used.

CABLUs and open-end cables for SIPAC 1 SU connectors  

 If  
 Then  
 Slot with  
 SLCN  
 SLMA8  
 SLMO8  
 STMD3  
 TM2LP  
 TMC161  
 TMDID2  
CABLUs for connection between connector panel (SIPAC 1 SU connectors) and MDFU-E (splitting strip for 16 TW):  
 •   S30269-Z100-A11: 3 m in length, short stripped length for MDFU-E slots 11-21 (see Figure 4-36)
 •   S30269-Z100-A21: 3 m in length, long stripped length for MDFU-E slots 1-10 (see Figure 4-36)
CABLU with 16 TW for connection between connector panel (SIPAC 1 SU connectors) and external patch panel S30807-K6143-X (SIVAPAC socket terminal strip):  
 •   S30267-Z362-A20: 2 m in length (refer to Figure 4-42)
Open-end cable (16 TW) for connection between backplane (SIPAC 1 SU connectors) and external patch panel:  
 •   S30267-Z192-A60: Open-end cable with 16 TW, 6 m in length
 •   S30267-Z192-A100: Open-end cable with 16 TW, 10 m in length
 •   S30267-Z192-A200: Open-end cable with 16 TW, 20 m in length
(Information on the required stripped lengths for open-end cables is provided in Figure 4-47.)
 Slot with  
 SLMA  
 SLMA21  
 SLMO2  
CABLUs for connection between connector panel (SIPAC 1 SU connectors) and MDFU-E (jumper strip for 25 TW):  
 •   S30269-Z100-A14: 3 m in length, short stripped length for MDFU-E slots 11-21 (see Figure 4-36)
 •   S30269-Z100-A24: 3 m in length, long stripped length for MDFU-E slots 1-10 (see Figure 4-36)
CABLU with 24 TW for connection between connector panel (SIPAC 1 SU connectors) and external patch panel S30807-K6143-X (SIVAPAC socket terminal strip):  
 •   S30267-Z363-A20: 2 m in length (refer to Figure 4-42)
Open-end cable (16 TW) for connection between backplane (SIPAC 1 SU connectors) and external patch panel:  
 •   S30267-Z192-A60: Open-end cable with 16 TW, 6 m in length
 •   S30267-Z192-A100: Open-end cable with 16 TW, 10 m in length
 •   S30267-Z192-A200: Open-end cable with 16 TW, 20 m in length
(Information on the required stripped lengths for open-end cables is provided in Figure 4-47.)
 different or no assignment  
The backplane sections of other boards and empty board slots must be covered with filler panels.  
1for selected countries only
2for U.S. only
Information on cable and connector assignment is provided in the board descriptions in Chapter 3 "Boards for HiPath 3000".