11.2  

System Configuration 
 
The following table indicates the maximum possible system configuration parameters for . It also shows when
 •   CMA or CMS is necessary
 •   analog trunk access is possible.

 Tabelle 11-1   HiPath Cordless Office - System Configuration for HiPath 3000 V8
 System  
 max. Number  
 Clock modules  
 Maximum number of base stations BS with connection via 1xUP0/E  
 Simultaneous calls per BS  
 max. Number
MTs
 
 Analog
trunk access
of the system
 
 SLC16N  
 SLCN  
 BS3/1  
 BS3/S  
 BS3/3  
 BS4  
 BS3/1  
 BS3/S  
 BS3/3  
 BS4  
 HiPath 3350  
 HiPath 3300  
 -  
 -  
 CMS  
 -  
 1  
 -  
 1  
 -  
 1/2  
 -  
 1/2  
 8  
 No  
 -  
 -  
 CMA  
 1  
 -  
 -  
 1  
 1/4  
 -  
 -  
 1/4  
 8  
 Yes  
 -  
 -  
 CMA  
 3  
 -  
 -  
 3  
 1/4  
 -  
 -  
 1/4  
 16  
 Yes  
 HiPath 3550  
 HiPath 3500  
 -  
 -  
 CMS  
 -  
 1  
 -  
 -  
 -  
 1/2  
 -  
 -  
 8  
 No  
 -  
 -  
 CMA  
 1  
 -  
 -  
 1  
 1/4  
 -  
 -  
 1/4  
 8  
 Yes  
 -  
 -  
 CMA  
 7  
 -  
 -  
 7  
 1/4  
 -  
 -  
 1/4  
 32  
 Yes  
 HiPath 3550  
 1  
 -  
 CMS  
 16  
 -  
 16  
 16  
 1/4  
 -  
 3/12  
 3/12  
 64 (with 1 SLC16N)  
 Yes  
 HiPath 3800  
 -  
 4  
 CMS  
 64  
 -  
 64  
 64  
 1/4  
 -  
 3/12  
 3/12  
 250 (with 4 SLCN) 1  
 Yes  
Explanations:  
 •   BS3/1 (S30807-H5482-X): is a base station that supports a maximum of 4 calls.
 •   BS3/3 (S30807-H5485-X): is a base station that supports a maximum of 12 calls when connected using three UP0/E interfaces.
 •   BS3/S (X30807-X5482-X100): The BS3/S single-cell base station guarantees the operation of a maximum of one base station on the UP0/E interfaces of the central board. It is not possible to operate additional base stations.
 •   BS4 (S30807-U5491-X): is a base station that supports a maximum of 12 calls when connected using three UP0/E interfaces. In the case of a direct connection, it is only permitted to make the connection via one UP0/E interface. The B channels in the base station BS4 require a license (see Chapter 8 "Licensing").
1Up to 128 handsets are possible at an SLCN.