3.3.48  

4SLA (not for U.S.), 8SLA, 16SLA (Not for U.S.) 
 
NOTE: Danger of damage to property due to surge voltage. The required lightning protection measures must be taken for this board, see Section 2.1.2 "Lightning Protection".  

Introduction  
The 4SLA, 8SLA, and 16SLA (Subscriber Line Analog) modules for analog T/R interfaces connect HiPath 3550 and HiPath 3350 (wall housing) to conventional analog telephones and supplementary equipment (such as, Group 3 fax machines and entrance telephone adapters).

Interfaces  
 Figure 3-130   4SLA (not for U.S.), 8SLA - Interfaces (S30810-Q2923-X200, -X100)
 

 Table 3-173   4SLA (not for U.S.), 8SLA Contact Assignments
 Contact  
 X2 (T/R ports 1 to 4)  
 X3 (T/R ports 5 to 8)  
 1  
 a 1  
 a 5  
 2  
 b 1  
 b 5  
 3  
 a 2  
 a 6  
 4  
 b 2  
 b 6  
 5  
 a 3  
 a 7  
 6  
 b 3  
 b 7  
 7  
 a 4  
 a 8  
 8  
 b 4  
 b 8  
 Figure 3-131   16SLA (not for U.S.) - Interfaces (S30810-Q2923-X)
 

 Table 3-174   16SLA (not for U.S.) - Contact Assignments
 Contact  
 X2
(T/R ports 1 to 4)  
 X3
(T/R ports 5 to 8)  
 X4
(T/R ports 9 to 12)  
 X5
(T/R ports 13-16)  
 1  
 a 1  
 a 5  
 a 9  
 a 13  
 2  
 b 1  
 b 5  
 b 9  
 b 13  
 3  
 a 2  
 a 6  
 a 1  
 a 14  
 4  
 b 2  
 b 6  
 b 10  
 b 14  
 5  
 a 3  
 a 7  
 a 11  
 a 15  
 6  
 b 3  
 b 7  
 b 11  
 b 15  
 7  
 a 4  
 a 8  
 a 12  
 a 16  
 8  
 b 4  
 b 8  
 b 12  
 b 16  
The operating mode (short or long line with the appropriate flash times) can be set up for each subscriber line interface with HiPath 3000/5000 Manager E (the menu settings: Set up station -> Station -> Param -> Flags).

Technical connection conditions  
 •   Maximum supply current: approximately 34 mA; maximum supply voltage: approximately 40 Vdc
 •   Ring voltage against negative supply voltage (a-wire (tip)/RING): two telephones maximum
 •   Range, see Section 2.7 "Interface-to-Interface Ranges"
 •   Loop current detection > 10 mA
 •   Ground button detection > 20 mA
 •   The transmission technology is set according to the specific country through the respectively entered country code (for country initialization, see Chapter 5 "Starting Up HiPath 3000").