3.3.35  

TLANI4R 
 
NOTE: Danger of damage to property due to surge voltage. The required lightning protection measures must be taken for this board, see Section 2.1.2 "Lightning Protection".  

Introduction  
The TLANI4R board provides four interfaces for the analog trunk connection (MSI: ground start or loop start) for HiPath 3500 and HiPath 3300 (19'-inch housing).
The interfaces for analog trunk connection support the CLIP feature and call detail recording with 12 kHz and 16 kHz impulses. Call detail recording is automatically selected in the country setting for the system. Call detail recording with 50 Hz impulses is not supported.
Not all board country variants support call detail recording with 12 kHz and 16 kHz impulses.  
Call detail recording can be activated and deactivated with HiPath 3000/5000 Manager E (Settings menu: Lines/networking ... -> Trunks -> (double-click) Parameters -> MSI flags -> Flags -> Charge module activated).
"Silent Reversal" is also supported, which is used to register the beginning and end of an outgoing call in different countries. It can be activated with HiPath 3000/5000 Manager E (Settings menu: Lines/networking ... -> Trunks -> (double-click) Parameters -> MSI flags -> Flags -> Silent Reversal).
The ÜFS (Supervisory Frequency System) trunks with direct inward dialing used in Austria are not supported.
Warning  
According to U.S. and Canadian installation instructions, analog trunks must be connected over fuse elements in compliance with UL 497A or CSA C22.2 No. 226.  

Interfaces  
 Figure 3-105   TLANI4R - Interfaces (S30810-K2953-X2xx)
 

Contact assignments  

 Table 3-136   TLANI4R - Contact Assignments
 RJ45 jack  
 X5, pin  
 Trunk connections 1-4  
 1  
 14  
 a, trunk 1  
 15  
 b, trunk 1  
 2  
 24  
 a, trunk 2  
 25  
 b, trunk 2  
 3  
 34  
 a, trunk 3  
 35  
 b, trunk 3  
 4  
 44  
 a, trunk 4  
 45  
 b, trunk 4  
 RJ45 jack  
 X5, pin  
 ALUM 1 + 2  
 5  
 54  
 b  
 ALUM1: Subsc. line module connection  
 55  
 a  
 6  
 64  
 b  
 ALUM2: Subsc. line module connection  
 65  
 a  
 7  
 74  
 b  
 ALUM1: Analog telephone connection  
 75  
 a  
 8  
 84  
 b  
 ALUM2: Analog telephone connection  
 85  
 a  

Jumper for setting the process for the analog trunk interfaces  
Process settings for the analog trunk interface is via X105 and X106 jumpers.
 •   Loop start setting = Pins 1-2 closed (default)
 •   Ground start setting = Pins 2 - 3 closed