3.3.29  

TCAS-2 and TCASR-2 (for selected countries only) 
 
NOTE: Danger of damage to property due to surge voltage. The required lightning protection measures must be taken for this board, see Section 2.1.2 "Lightning Protection".  

Introduction  
The following cards - one per system - can be used for V5.0 SMR -10 and later to support country-specific CAS (Channel Associated Signaling) protocols:
 •   TCAS-2 (S30810-Q2945-X) in HiPath 3550
 •   TCASR-2 (S30810-K2945-X) in HiPath 3500
Please note that the cards listed can only be used in slots 7 and 9.
Each of the cards features two E1-CAS interfaces, which together support up to 60 B channels. Since HiPath 3550 and HiPath 3500 each support a maximum of 30 B channels, a total of up to 30 B channels can be used per card.
Direct connection to the MINI BNC connectors on each card is only possible for coaxial trunks (75 ohms). An external impedance converter (F31505-E1-A146) must be used for symmetrical trunks (120 ohms).
TCAS-2 and TCASR-2 function as converters, which convert the Euro-ISDN protocol on an S2M link to the Channel Associated Signaling protocol CAS. In contrast to the predecessor TMCAS board, TCAS-2 and TCASR-2 communicate directly with the central control in the system. All signaling and data traffic goes through TCAS-2 and TCASR-2. Unlike TMCAS, connection to an S2M board is therefore not required.
 Figure 3-86   TCAS-2 (S30810-Q2945-X) (for selected countries only) - Figure
 

Interfaces and jumpers  
 Figure 3-87   TCAS-2, TCASR-2 (for selected countries only) - Interfaces and Jumpers
 

Settings  

 Table 3-118   TCAS-2, TCASR-2 (for selected countries only) - Jumper Functions
 Jumper  
 Function  
 Setting  
 Pins 1-2 closed  
 Pins 2-3 closed  
 X11  
 Sets the V.24 baud rate  
 See Table 3-119  
 X12  
 X14  
 X13  
 Deletes the flash memory  
 Flash memory is deleted (all sectors apart from U-boot (firmware)).  
 Flash memory is not deleted.  
 (default setting)  
 X16  
 Resets card  
 Reset performed.  
 Reset not performed.  
 (default setting)  
 X17  
 Hardware watchdog  
 Watchdog active.  
 (default setting)  
 Watchdog is not active.  

 Table 3-119   TCAS-2, TCASR-2 (for selected countries only) - Jumper for Setting the V.24 Baud Rate
 V.24 baud rate
(Kbps)  
 Jumper  
 X11  
 X12  
 X14  
 9.6  
 (default setting)  
 Open  
 Open  
 Open  
 19.2  
 Open  
 Open  
 Closed  
 38.4  
 Closed  
 Open  
 Closed  
 57.6  
 Open  
 Closed  
 Closed  
 115.2  
 Closed  
 Closed  
 Closed  
 9.6  
 All other configurations  

Connections  
 Figure 3-88   TCAS-2, TCASR-2 (for selected countries only) - Connections
 

TCASR-2 front panel  
 Figure 3-89   TCASR-2 (for selected countries only) - Front Panel
 

Seven-segment display  
The card's software status can be ascertained on the basis of the seven-segment display. For this a distinction is made between the following boot phases:
 •   U-boot (firmware) states
   
 Table 3-120   TCAS-2, TCASR-2 (for selected countries only) - U-boot (firmware) States
 Display  
 Meaning  
 
Initializing hardware  
Downloading DSP (Digital Signal Processor) firmware  
Downloading FPGA (Field Programmable Gate Array) firmware  
 
Accessing flash EPROM (Save and Delete)  
 
Activating built-in self test BIST (BIST1 or BIST2)  
 
Administration (Service PC connected)  
 
Copying software (from SDRAM to FEPROM)  
 
Downloading image file (Linux and CAS application)  
 
Initializing the Linux operating system  
 
Error  
 
Resetting card  
 
U-boot (firmware) operational (decimal point flashing)  
 •   Linux operating system states
   
 Table 3-121   TCAS-2, TCASR-2 (for selected countries only) - Linux Operating System States
 Display  
 Meaning  
 
Linux kernel boot  
 
User space boot  
 
Check and mount flash  
 
Error found, mounted file system rebuild, reboot  
 
Mounting flash file system  
 
Error mounting flash (flashing display)  
 
Configuring network interface  
 
Loading real-time kernel modules  
 
Loading board-specific modules  
 
Core files available  
 •   CAS application software states
   
   Figure 3-90   TCAS-2, TCASR-2 (for selected countries only) - CAS Application Software States
 

Modem (optional)  
 Figure 3-91   TCAS-2, TCASR-2 (for selected countries only) - Optional Modem
 
The analog modem (modem kit F31505-E1-A147) is an optional subboard for the TCAS-2 and TCASR-2 cards, which is plugged into the X20 and X21 ports. This facilitates remote administration of the CAS protocol converter on the TCAS-2 and TCASR-2 cards (see Page 3-259).

Administration of the CAS protocol converter  
A separate tool, the CAS Manager, is used to download the software and administer the TCAS-2 and TCASR-2. The CAS Manager software is stored on a CD supplied with the card. For information on how to install the CAS Manager software on the Service PC, refer to the readme file.
The following options are available for accessing the cards:
 •   Via the V.24 interface (9-pin MINI DIN jack X803) and the connection cable C39195-A9700-B532.
 •   Via the Ethernet (10/100BaseT) interface (RJ45 jack X804).
 •   Via the optional analog modem (modem kit F31505-E1-A147). In this case, you will need to establish a connection from the analog modem (RJ45 jack X805) to a free port in an analog subscriber line module via the RJ45 cable C39195-Z7208-A10 supplied with the modem kit (see Figure 3-93).
 Figure 3-92   TCAS-2, TCASR-2 (for selected countries only) - Connection Options for Card Administration using CAS Manager
 
 Figure 3-93   TCAS-2, TCASR-2 (for selected countries only) - RJ45 Cable C39195-Z7208-A10
 

Assigning the CAS cable  
The following options are available for connecting network terminators (NT), multiplexers (MUX) or modems to the TCAS-2 and TCASR-2 cards (MINI BNC connections):
 •   Coaxial trunk (75 ohms), length = 10 m
   
 Table 3-122   TCAS-2, TCASR-2 (for selected countries only) - Assignment of the CAS Cable C39195-A7700-B13
 Wire  
 Function  
 MINI BNC connector  
 BNC connector  
  1  
 Receive, Tip  
 Conductor  
 Conductor  
 Receive, Ring  
 Shield  
 Shield  
 2  
 Transmit, Tip  
 Conductor  
 Conductor  
 Transmit, Ring  
 Shield  
 Shield  
   
   Figure 3-94   TCAS-2, TCASR-2 (for selected countries only) - CAS Cable C39195-A7700-B13
 
 •   Symmetrical trunk (120 ohms)
    The impedance converter F31505-E1-A146 must be used for connecting to a symmetrical trunk.
   
   Figure 3-95   TCAS-2, TCASR-2 (for selected countries only) - Impedance Converter F31505-E1-A146
 
 •   CAS cable shield contacts
    To ensure sufficient electromagnetic shielding (according to EN 55022), both shielded CAS cables must be contacted at the appropriate points on the HiPath 3550/HiPath 3350.
    Procedure:
    Fix the cable shielding (B) for both CAS cables (A) via cable binder (C) to the T tongue (D) of the housing, so a continuously conductive contact is created between the conductive tape on the cable shielding and the housing (see figure).
   
   Figure 3-96   CAS cable - shield contacting