3.2.2  

CBRC 
 
NOTE: Danger of damage to property due to surge voltage. The required lightning protection measures must be taken for this board, see Section 2.1.2 "Lightning Protection".  

Introduction  
The CBRC board (Central Board Rack Com) performs all central control and attendant functions for HiPath 3500 and HiPath 3300.
This description refers to the following versions of central CBRC board:
 •   CBRC S30810-Q2935-Z401: Implemented from V6.0 Rel. 10 or later and V5.0 Rel. 15 or later.
Essential new functions:
   -   Integration of the functionality of the LIM subboard
   -   Increase of the ring voltage of analog station interfaces (T/R) to approx. 65 Veff
 •   CBRC S30810-Q2935-Z301: implemented in V5.0 or later
Essential new function: CLIP
Differences between both CBRC versions are indicated at the appropriate point in the following description.

Subboards  
The following subboards can be used depending on the application:
 •   Clock module CMA or CMS (optional)
 •   MMC multimedia card
 •   IMODN integrated modem card new (optional)
 •   MPPI music on hold (optional)
 •   Entry Voice Mail EVM (optional): Pluggable up to HiPath 3000/5000 V7, securely soldered as of HiPath 3000/5000 V8.
 •   LAN Interface Module LIM (optional, for CBRC S30810-Q2935-Z301 only)

Outputs, interfaces  
 •   Ethernet (10 BaseT)/10 MBit) LAN interface, only in CBRC S30810-Q2935-Z40
The interface can be used for administration via HiPath 3000 Manager E and CTI functions (TAPI 120 V2.0). However, bear in mind that the number of BHCAs (Busy Hour Call Attempts = number of connection attempts during busy traffic hours) is restricted to 400 at a maximum of six TAPI ports. The use of "power dialers" is not approved.
    The ETHERNET-LAN interface is deactivated by the system software deactivated as soon as an HG 1500 board is inserted.
 •   Eight digital UP0/E subscriber lines
For example, UP0/E workpoint clients or BS3/1 base stations for HiPath Cordless Office can be connected here.
 •   Four analog T/R subscriber lines
For U.S. only: These interfaces do not support the connection of external extensions via OPS (Off-Premises Station) signaling.
CBRC S30810-Q2935-Z401: The interfaces supply a ring voltage of approx. 65 Veff.
CBRC S30810-Q2935-Z301: The T/R interfaces supply a ring voltage of approx.  35 Veff. Depending on the terminals connected, we cannot exclude the possibility of errors occurring during ringing state.
 •   Two digital S0 interfaces (CO (default) or station)
 •   Backplane (CUCR or CUPR) connection via slots 1 (X11), 2 (X5) and 3 (X6)
 •   Music on hold: MPPI, EXMR
 •   Options bus (O bus)
 •   V.24 interface

Switches and indicators  
 •   Reset/reload switch
   -   Switch pressed < 5 s = Reset activated
   -   Switch pressed > 5 s = Reload activated (RUN LED off indicates that a reload is in progress)
 •   RUN LED
LED status meaning is explained in the following table.
   
 Table 3-10   CBRC - LED Status Meaning
 RUN LED  
 Meaning  
 off  
No power  
 On  
Reset switch pressed briefly  
 Off  
Reset switch held down for more than 5 seconds (LED is extinguished to acknowledge that a reload has begun)  
 On  
System boot  
 off
for 0.1 s  
Load operation: APS in SDRAM, loadware, and card data.  
 Flashing
0.5 s on/0.5 s off  
Normal operating state (zero load)1  
 Flashing
0.1 s on/0.1 s off  
MMC removed or defective  
1The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm.

Figure CBRC S30810-Q2935-Z401  
 Figure 3-3   CBRC Board (S30810-Q2935-Z401)
 
Disconnecting the battery buffer by unplugging the X27 jumper is necessary only for testing (module test at the factory). Disconnection does not necessarily delete the customer database (CDB). To delete the CDB, use the reset switch.  

Figure CBRC S30810-Q2935-Z301  
 Figure 3-4   CBRC Board (S30810-Q2935-Z301)
 
Disconnecting the battery buffer by unplugging the X27 jumper is necessary only for testing (module test at the factory). Disconnection does not necessarily delete the customer database (CDB). To delete the CDB, use the reset switch.  

X1 and X3 contact assignments  

 Table 3-11   CBRC - X1 and X3 Contact Assignments
 Contact  
 Connector X1  
 Connector X3  
 UP0/E  
 T/R  
 14  
 UP0/E port 1a  
 T/R port 1a  
 15  
 UP0/E port 1b  
 T/R port 1b  
 24  
 UP0/E port 2a  
 T/R port 2a  
 25  
 UP0/E port 2b  
 T/R port 2b  
 34  
 UP0/E port 3a  
 T/R port 3a  
 35  
 UP0/E port 3b  
 T/R port 3b  
 44  
 UP0/E port 4a  
 T/R port 4a  
 45  
 UP0/E port 4b  
 T/R port 4b  
 54  
 UP0/E port 5a  
 -  
 55  
 UP0/E port 5b  
 -  
 64  
 UP0/E port 6a  
 -  
 65  
 UP0/E port 6b  
 -  
 74  
 UP0/E port 7a  
 -  
 75  
 UP0/E port 7b  
 -  
 84  
 UP0/E port 8a  
 -  
 85  
 UP0/E port 8b  
 -  

S0 interface assignment  

 Table 3-12   CBRC - S0 Interface Assignment (RJ45 Jacks)
 X9
Pin  
 S0 Port 1  
 X9
Pin  
 S0 Port 2  
 11  
 -  
 21  
 -  
 12  
 -  
 22  
 -  
 13  
S0 port 1, transmit +  
 23  
S0 port 2, transmit +  
 14  
S0 port 1, receive +  
 24  
S0 port 2, receive +  
 15  
S0 port 1, receive -  
 25  
S0 port 2, receive -  
 16  
S0 port 1, transmit -  
 26  
S0 port 2, transmit -  
 17  
 -  
 27  
 -  
 18  
 -  
 28  
 -  

V.24 interface assignment  

 Table 3-13   CBRC - V.24 Interface Assignment (SUB-D Plug)
 X18, Pin  
 Signal  
 Description  
 1  
 -  
Not used  
 2  
 RxD A  
Receive data, channel A  
 3  
 TxD A  
Transmit data, channel A  
 4  
 -  
Not used  
 5  
 0 V  
Ground  
 6  
 -  
Not used  
 7  
 RTS A  
Request to send, channel A  
 8  
 CTS A  
Clear to send, channel A  
 9  
 -  
Not used  

LAN connector assignment  
CBRC S30810-Q2935-Z301: The Ethernet LAN interface is provided by the optional LIM subboard.

 Table 3-14   CBRC - LAN Connector Assignment (RJ45 Jack) via LIM
 Pin  
 Signal  
 Description  
 1  
 Tx +  
Transmit +  
 2  
 Tx -  
Transmit -  
 3  
 Rx +  
Receive +  
 4  
 -  
Not used  
 5  
 -  
Not used  
 6  
 Rx -  
Receive -  
 7  
 -  
Not used  
 8  
 -  
Not used  

Default Numbering Plan When Using CBRC in HiPath 3500  

 Table 3-15   Default Numbering Plan When Using CBRC in HiPath 3500
 Station  
 Int. call no.  
 DID no.  
 Port  
 UP0/E host
(master)  
 100  
 100  
 UP0/E 1  
 101  
 101  
 UP0/E 2  
 102  
 102  
 UP0/E 3  
 103  
 103  
 UP0/E 4  
 104  
 104  
 UP0/E 5  
 105  
 105  
 UP0/E 6  
 106  
 106  
 UP0/E 7  
 107  
 107  
 UP0/E 8  
 UP0/E client
(slave)  
 500  
 500  
 UP0/E 1  
 501  
 501  
 UP0/E 2  
 502  
 502  
 UP0/E 3  
 503  
 503  
 UP0/E 4  
 504  
 504  
 UP0/E 5  
 505  
 505  
 UP0/E 6  
 506  
 506  
 UP0/E 7  
 507  
 507  
 UP0/E 8  
 T/R  
 108  
 108  
 T/R 1  
 109  
 109  
 T/R 2  
 110  
 110  
 T/R 3  
 111  
 111  
 T/R 3  
 EVM  
 112  
 112  
 EVM-1  
 113  
 113  
 EVM-2  
 Line  
 Code  
 Port  
 S0  
 CO PP  
 7801  
 S0 1-1  
 7802  
 S0 1-2  
 7803  
 S0 2-1  
 7804  
 S0 2-2  

Default Numbering Plan When Using CBRC in HiPath 3300  

 Table 3-16   Default Numbering Plan When Using CBRC in HiPath 3300
 Station  
 Int. call no.  
 DID no.  
 Port  
 UP0/E host
(master)  
 11  
 11  
 UP0/E 1  
 12  
 12  
 UP0/E 2  
 13  
 13  
 UP0/E 3  
 14  
 14  
 UP0/E 4  
 15  
 15  
 UP0/E 5  
 16  
 16  
 UP0/E 6  
 17  
 17  
 UP0/E 7  
 18  
 18  
 UP0/E 8  
 UP0/E client
(slave)  
 51  
 51  
 UP0/E 1  
 52  
 52  
 UP0/E 2  
 53  
 53  
 UP0/E 3  
 54  
 54  
 UP0/E 4  
 55  
 55  
 UP0/E 5  
 56  
 56  
 UP0/E 6  
 57  
 57  
 UP0/E 7  
 58  
 58  
 UP0/E 8  
 T/R  
 19  
 19  
 T/R 1  
 20  
 20  
 T/R 2  
 21  
 21  
 T/R 3  
 22  
 22  
 T/R 3  
 EVM  
 23  
 23  
 EVM-1  
 24  
 24  
 EVM-2  
 Line  
 Code  
 Port  
 S0  
 CO PP  
 801  
 S0 1-1  
 802  
 S0 1-2  
 803  
 S0 2-1  
 804  
 S0 2-2