3.3.10 |
PBXXX (for selected countries only) |
Introduction |
| The PBXXX (Peripheral Board XXX) module can be used in HiPath 3800 to support country-specific CAS protocols. |
|
| The PBXXX board converts the Euro-ISDN protocol on an S2M link into the Channel Associated Signaling (CAS) protocol. The board functions only in conjunction with a DIUN2. There is no direct connection between the PBXXX board and the system's central control unit. The DIUN2 handles all signaling and data traffic. |
| The following combination options are possible: |
| • | 1 x DIUN2 + 1 x PBXXX (see Page 3-129) The PBXXX board must be plugged in on the left next to the DIUN2. |
| • | 1 x DIUN2 + 2 x PBXXX (see Page 3-132) The PBXXX boards must be plugged in on the left and right next to the DIUN2. |
| Up to four PBXXX boards can be installed in a HiPath 3800. For power supply reasons, a maximum of two PBXXX can be installed in a cabinet. |
Administration of the CAS protocol converter |
| Use the ECGM tool for administration. For information on installing the software on the service PC and on the required settings, see Page 3-303. |
| The C39195-Z7267-C2 cable can be used with a C39334-Z7080-C2 adapter (9-pin Sub-D jack - 25-pin Sub-D jack) to connect the PBXXX (port M) and the service PC. |
Notes on setup using HiPath 3000/5000 Manager E |
| Because the PBXXX card is not recognized by the hardware, offline configuration is required with HiPath 3000/5000 Manager E. Either "DIUN2 + PBXXX" or "DIUN2 + 2PBXXX" should be specified as the board to be configured. After configuration, the module data can be seen in HiPath 3000/5000 Manager E. However, this is only visible in the software configuration, as the PBXXX card was only configured on the software side. |
| Note: The offline configuration of the PBXXX serves solely to visualize the card with HiPath 3000/5000 Manager E. |
Front panel |
Seven-segment display |
| The board statuses listed in the following table are displayed. |
Connection 1x DIUN2 + 1 x PBXXX |
| The figure below shows an example of a DIUN2 with one PBXXX in the basic cabinet. |
|
Connection 1x DIUN2 + 2 x PBXXX |
| The figure below shows an example of a DIUN2 with two PBXXXs in the basic cabinet. |
|
Assigning both CAS cables |
| The following CAS cables are connected to the backplane via two APPCU adapters: |
| • | symmetrical line (120 ohms), open end |
| • | coaxial line (75 ohms) |
| HiPath 3000/5000 V8, Service Documentation, Issue 10 | up ![]() |
|
![]() |
||