3.2.10  

LIM 
 
Caution  
The LAN interface module must not be plugged in or out when the system is energized.  
Place the central control board on a flat surface before inserting the LIM subboard.  
The spacing bolts supplied guarantee the correct insertion of the subboard, so you should always mount them (see Figure 3-7).  
Otherwise you may damage the board.  

Introduction  
The LAN Interface Module LIM (S30807-Q6930-X) is an optional plug-in card for all central control boards of HiPath 3000 with the exception of the CBSAP (HiPath 3800), the CBCC (HiPath 3550, HiPath 3350) from S30810-Q2935-A401 or later, and the CBRC (HiPath 3500, HiPath  3300) from S30810-Q2935-Z401 or later.
The board provides an Ethernet (10BaseT/10 megabit) LAN connector via an 8-pin RJ45 jack.
The LIM module can be used for administration via HiPath 3000/5000 Manager E and for CTI functions (TAPI 120 V2.0). Bear in mind, however, that the number of  BHCAs (Busy Hour Call Attempts = number of connection attempts during busy traffic hours) is restricted to 400 at a maximum of six TAPI ports. The use of "power dialers" is not approved.
In V6.0 or later, the system software deactivates an existing LIM module when an HG 1500 board is inserted. You cannot operate the LIM module and a HG 1500 board simultaneously in a HiPath 3000.

RJ45 jack assignment  

 Table 3-20   LIM - RJ45 Jack Assignment
 Pin  
 Signal  
 Description  
 1  
 Tx +  
Transmit +  
 2  
 Tx -  
Transmit -  
 3  
 Rx +  
Receive +  
 4  
 -  
Not used  
 5  
 -  
Not used  
 6  
 Rx -  
Receive -  
 7  
 -  
Not used  
 8  
 -  
Not used