9.9.6 |
Sensors |
| Sensors is used to configure the control inputs which trigger the corresponging functions in the communication system. |
9.9.6.1 |
Sensor list table |
| The sensors to be administered are listed in the list. |
9.9.6.2 |
Area: Sensor |
Sensor type |
| The sensors can be assigned to different types in accordance with the above functionalities. |
Entry in Error History |
| Allows you to select whether or not error 1/19 is to be entered in the error history. |
| Only active for the sensor type ALARM. |
Destination call number |
| An associated a/b port is programmable for the sensors. This port is called by the communication system once a setup signal has been received. The calling party then overrides this connection. A recorded announcement can be activated via an answering machine connected to this port, which informs the dialed station of the response of the sensor. An a/b port programmed in this way cannot be contacted from the outside. |
| If an external phone number or an EVM was programmed for a sensor instead of an a/b port, the connection is established, but no acoustic information is transmitted regarding the sensor response. |
|
| If the phone number is external, the called station can at least - if CLIP is active- see the origin of the call. |
Announcement setup, phone number |
| Input of the port to which the announcement device, answering machine or PhoneMail device is connected. |
Message texts box control data |
| Input of the control string with a maximum of 24 characters for the PhoneMail system (mailbox call number). |
| If the connection has been established, the control string is transmitted to the recorded announcement port. If a recorded announcement port is not available, the control string is transmitted to the destination. |
Application example for HiNet VS1600 |
| The failure of the fan is detected by a temperature sensor and is signaled via a LED on the front panel. If Entry in Error History is activated, this alarm is stored additionally in the error history. |
Sensor name/signaling text |
| Name of the sensor, max. 16 characters |
| In the case of internal destinations, the sensor name appears in the display. |
| If Entry in Error History is activated, only up to 10 characters can be entered for the sensor name. |
Number of calls |
| The number of attempts that are to be made to contact the destination station are entered here. |
Timer multipliers |
| |