8.19.6  

Maintenance | Base Station Status (not in the USA) 
 
Base Station Status can be used to display the status for the base stations.

8.19.6.1  

Area: UPN port 
All UPN ports of the associated base stations are listed in the table. A specific base station for which the status is to be displayed can be selected from this table (in advance data have to be loaded).

Save  
When you click on the Save button, the status of the Cordless Base Stations (BS) connected to the communication system are saved.

Read data  
When you click on the Read data button, the status of the Cordless Base Stations (BS) that are connected to the communication system are read out.

8.19.6.2  

Area: Base station data V1 + V2 

Base station  
The number of the selected base station is displayed.  
Software version  
The software version of the base station is displayed here.  
Hardware version  
The hardware version of the base station is displayed here.  
Status  
The status of the associated port is displayed here.  
Possible statuses:  
   -   Port active
   -   Port not connected
   -   Port blocked
   -   Port connected, inactive
   -   1st expansion port for ... (no. of main port)
   -   2nd expansion port for ... (no. of main port)
Overload  
Number of the overload situations on the UP0/E interface.  
Restarts  
Number of times the base station was restarted.  
Delete  
The counter is reset with Clear. The Clear button can currently not be activated; the meter is deleted each time a new query is executed.  

8.19.6.3  

Area: SLC16-wide 

Lost Calls  
Number of calls that could not be processed due to a lack of resources.  
SLMC Overload  
Number of overload situations on the SLC16 card.  
A minimum number of pool elements is not available on the SLC16 card.  
All incoming connections will be rejected by the SLC16 IWU until the overload situation returns to normal.  
LR Roam  
LR Roam counts each connection for a mobile telephone with a default PMID and located at a different SLC.  
Number of locate request messages that reported roaming (i.e. the current location of the mobile telephone has changed).  
Each time the mobile phone is switched on, a locate request is executed. If the mobile phone is switched off and switched on again in another radio cell, this meter does not execute a count.  
LR Async  
LR Async counts each connection for a mobile telephone with a default PMID where the SLC is unchanged.  
This refers to the number of locate request messages which reported layer asynchronicity (i.e. the current location of the mobile phone is unchanged).  
The count is always performed for the home SLC, and only if a connection is actually set up or supports the CHO with the default PMID.  
In addition, the criteria for a location update must be met for each connection, i.e. a LOCATE request has been received or the security procedures, authentication (and coding) have been implemented for the link.  
HDLC Error  
Number of uncritical HDLC error messages that were not reported to the communication system (overflow, underrun, CRC error).  
CMI Version  
The current coredless version is displayed here.  

8.19.6.4  

Area: Base station data V2 

L1/L2 Error  
Number of L1/L2 errors that occurred in the base station.  
Abnormal Release  
Number of interrupted calls in the base station.  
Calls per BS  
Number of calls made via the base station (both incoming and outgoing).  
Hopping Mode  
CMI Version 2 systems always operate in fast hopping mode, i.e. all frequency - time slot pairs can be used. This provides for 120 duplex channels.  
In the case of base stations with slow hopping, only every second frequency - time slot pair can be used. This means than only 60 duplex channels are available. All cordless version 1 systems operate in slow hopping mode.  
BHO Count OK  
Number of successfully completed intracell handovers (bearer handovers BHO), i.e. successful transfer of the carrier frequency and/or the time slot within a radio cell.  
Not supported by Hicom cordless EM V2.1 and V2.2. Although the meter is not supported, the Bearer Handover feature is available.  
BHO Count not OK  
Number of intracell handovers that failed (bearer handovers BHO).  
Not supported by Hicom cordless EM V2.1 and V2.2. Although the meter is not supported, the Bearer Handover feature is available.  
Intra SLC handover  
Number of handover procedures within the SLC16 card. This is counted in the new base station.  
Inter SLC handover  
Number of handover procedures between SLC16 cards. This is counted in the new base station.  
Not available up until and including Hicom 150 E Office Rel. 2.2 of the Hicom 150 E Office.  

See also:  
   -   HiPath 3000/5000 Service Manual, HiPath Cordless Office