11.5  

Remote Administration of HiPath 3000 via PPP 
 

Definition  
You can administer multiple HiPath 3000 systems from a central service center via PPP (point-to-point protocol). Each HiPath 3000 is addressed via its PSTN (public switching telephone network) interface.
You must enter a router call number (DID number) for every PSTN interface in the service center for external access to HiPath 3000. This number is not the station number previously used for administration via an integrated digital modem (B channel) or integrated analog modem (IMODC).
For analog modem there are the following specific values/parameters (for IMODC):  
Baud rate: 9600 baud, 19200 baud, 38400 baud or 57600 baud.  
You can establish a connection between the service center and HiPath 3000 via the integrated digital modem (B channel) or the integrated analog modem (IMODC). The point-to-point protocol (PPP) is used in both cases for data exchange.
 Figure 11-5   Remote Administration of HiPath 3000 via PPP
 
If the connection is established via callback, HiPath 3000 first of all denies a connection request from the service center (HiPath 3000/5000 Manager E). A callback is then set up to the service center's calling party number transferred via the PSTN connection's D channel.

Model-Specific Data  

 Subject  
 HiPath 3800  
 HiPath 3550  
 HiPath 3500  
 HiPath 3350  
 HiPath 3300  
Feature available in  
 x  
 x  
 x  
Hardware requirements  
 CBSAP  
 CBCC or
CBRC  
 CBCC or
CBRC  
Software requirements  
 V5.0 or later  
 V1.2 or later  
 V1.2 or later