7.2.16 |
Dialing Rules Table |
| The following is a sample dialing rules table. The dialing rules table determines the following: |
| • | The way the digits entered by the user are converted and dialed by the system |
| • | The route on which dialing will take place |
| • | The maximum amount of time the LCR function has to control dialing |
| • | Up to 254 dial rules, each up to 40 characters long, can be defined. |
| Dial rules are defined by the following parameters: |
| A: Repeat remaining fields (transmit). |
| D (n): Dial a digit sequence (1 to 24 digits). |
| E (n): Repeat field (1 to 10) from dial plan. |
| M (n): Authorization code (1 to 16). This letter must not be in the final position. |
| P (n): Pause (1 to 60 times the system-wide pause unit). |
| S: Switch, changes signaling methods from DP to DTMF (with CONNECT, PROGRESS or CALL PROC with PI). |
| C: Access code |
| U: Use subaddress signaling method. |
| N (n): Network SFG (1 to 5) or Band Number (1) |
| |
| The dialing rules provide access to different carriers via digit translation. The dialing rules address the dial plan fields selectively for the following operations: |
| • | Repeating digits |
| • | Suppressing digits |
| • | Exchanging digits |
| • | Inserting digits |
| • | Inserting pauses |
| • | Switching the signaling method |
| • | Detecting a dial tone. |
Using the A Parameter |
| The parameter A ensures that all subsequent digit fields are transmitted. The reference point is the last field indicator preceding A. The parameter A can occur more than once in the string and can be placed in any position. The AA combination has the same effect as A. The E1A combination is permitted only at the beginning of a string. |
Using the D Parameter |
| The parameter D (n) can occur more than once in the string and can be placed in any position. It can be surrounded by any parameter. It should be no more than 25 characters long. |
Using the E Parameter |
| The parameter E (n) can occur more than once in the string and can be placed in any position. The parameter E (n) can be arranged in any order, depending on n. A specific field can be addressed multiple times, including in sequence. With the exception of the E1A combination, E (n) can be surrounded by any other parameters. The n can be any number between one and 10. |
Using the M Parameter |
| The parameter M (n) can occur only once in the string. This letter must not be in the final position. The n can be any number between one and 16. |
Using the P Parameter |
| The parameter P (n) can occur more than once in the string and can be placed in any position. It can be surrounded by any parameter. The pause length is n times the length of the system pause. The n can be any number between one and 60. |
Using the S Parameter |
| The parameter S can occur only once in the string and should not be placed in the final position in the string. It cannot precede the C parameter. |
Using the C Parameter |
| The parameter C can occur only once in the string. The digits following C are sent without dial pause. The parameter C is used for carrier access with single stage, two stage, DICS and PRI. It cannot be used after S. |
Using the U Parameter |
| The parameter U can occur only once in the string. It should not be placed in the final position in the string. The subsequent characters are again selected in INFO. The following parameters may not be used after U: |
| S |
| P |
| C |
| M |
Using the N Parameter |
| The parameter N can occur only once in the string and should not be placed in the first position. The subsequent digits are the SFG or the band number, depending on the calling service. |
Authorization Code |
| Up to 16 authorization codes with a maximum of 16 digits can be entered for accessing services from different carriers. The codes may be used for accessing special common carriers or adding additional digits to a dial string as part of the outdial rule. |
Example: |
53276543 |
| One secure authorization code is provided (displayed as **********). |
| HiPath 3000/5000 V8, Feature Description, Issue 10 | up ![]() |
|
![]() |
||