3.2.4 |
Automatic COS Changeover after Timeout |
| Implementing features, see also Manager E Automatic COS Changeover |
Definition |
| The previous COS changeover function (see Section 3.2.3 "System Telephone Lock (Changeover)") could only distinguish between day and night service. This changeover type is valid for all stations. |
| With automatic COS changeover, stations are combined to form profiles (for example, management, sales). A schedule can be configured for each profile. This defines which COS is to be used for which timeslot during the week. |
Connection between Automatic COS and Automatic Night Service |
| The COS feature is correlated with automatic/manual day/night service. The following distinction is made: |
| • | The call destination is reached via call management This is implemented via call management and is independent of automatic COS changeover. There are different call lists for day and night. |
| • | Intercept destinations The intercept destination is only determined by automatic/manual day/night service. |
| • | COS Group: At night, the relationship between the COS group and the station is fixed (configurable). This is not affected by automatic COS changeover. During the day, the COS group can switch between specific times of the day if "Automatic COS" is set system-wide. Alternatively, if "Automatic COS" is not set, the COS group has a fixed (configurable) relationship with the station. |
General Description |
| • | If "Automatic COS" is not set system-wide, no changes are made to the COS group that is currently set. A station can have a different COS group for day and night. |
| • | If "Automatic COS" is set system-wide for the day, the profile and schedule that is configured will determine the COS group that is assigned to a station. At night, the station has the same COS group as previously assigned. Each profile has a different schedule to which the relevant COS group (CG) is assigned. |
|
| Figure 3-3 | Example of a schedule
|
| • | Manual activation of the lock code overwrites automatic mode for the associated station. |
| • | In the default scenario, automatic changeover of COS classes is deactivated. The existing COS class and call forwarding algorithm are applied. |
| • | Automatic COS changeover and day/night service do not function across all nodes. |
| • | Only one time zone is supported by the system. Remote station groups working in different time zones are set to the system's time zone. |
Model-Specific Data |
| |
Dependencies/Restrictions |
| HiPath 3000/5000 V8, Feature Description, Issue 10 | up ![]() |
|
![]() |
||
| Disclaimer & Copyright | ID: P31003H3580F100017618 | 2011-02-07 |