12.3.2 |
Manual Error Correction Without HiPath 3000/5000 Manager E |
Manually activating a restart (reset)/reload |
| Pressing the reset button on the central control board of HiPath 3000 |
| • | initiates a Reset (hard restart of the entire system with the current CDB) if the button is pressed for less than 5 seconds. The RUN LED lights up when the Reset button is pressed. |
| • | initiates a Reload if the button is pressed longer than 5 seconds. The Run LED disappears after approximately five seconds as verification that the reload has been initiated. The entire content of the customer database is replaced by its default version. All country and customer-specific settings are lost. |
|
Locking out and releasing boards and ports |
| You can lock out and release ports using the lockout switch located on the board. The lockout prevents renewed seizure after the current connection has finished. It creates |
| • | a port lockout in an outgoing direction on analog trunk boards. |
| • | a port lockout in outgoing and incoming directions on trunk boards. |
| • | a lockout of the entire board for subscriber line modules. |
| HiPath 3000/5000 V8, Service Documentation, Issue 10 | up ![]() |
|
![]() |
||