4.1.6 |
Connecting the Cable to the Backplane |
|
Connection options |
| Peripheral devices can be connected up to the HiPath 3800 in a number of different ways: |
| • | SIVAPAC connector on the backplane for connecting the external main distribution frame via CABLUs (prefabricated cabling units) or for connecting external patch panels (see Section 4.1.6.4 "Connecting Peripherals to the SIVAPAC Connector on the Backplane"). |
| • | Connector panels with RJ45 jacks for direct connection of peripherals (see Section 4.1.6.5 "Connecting Peripherals to the Connector Panels with RJ45 Jacks"). The connector panels are clipped onto the SIVAPAC connectors on the backplane. |
| • | For U.S. Only: Connector panels with CHAMP jack for direct connection of peripherals (see Section 4.1.6.6 "Connecting Peripherals to the Connector Panels with CHAMP Jack (for U.S. only)"). The connector panels are clipped onto the SIVAPAC connectors on the backplane. |
| • | Connector panels each with two SIPAC 1 SU connectors for connecting the external mail distribution frame MDFU-E or external patch panels using CABLUs (see Section 4.1.6.7 "Connecting Peripherals to Connector Panels with SIPAC 1 SU Connectors"). The connector panels are clipped onto the SIVAPAC connectors on the backplane. |
| The type of connection used will be decided in consultation with the customer on conclusion of the agreement. The cabinets will be delivered accordingly with or without clipped-on connector panels. |
4.1.6.1 |
Backplane of the Basic Cabinet |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4.1.6.2 |
Expansion Cabinet Backplane |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4.1.6.3 |
Connecting Cables Between the Basic and Expansion Cabinet |
| The connection cable C39195-Z7611-A10 has to be connected up for feeding the HDLC, PCM, and clock signals from the basic cabinet to the expansion cabinet: |
| • | Basic cabinet = X201 jack |
| • | Expansion cabinet = DBSAP board |
|
4.1.6.4 |
Connecting Peripherals to the SIVAPAC Connector on the Backplane |
| The boards should be installed in the cabinets as described in Section 4.1.5 "Installing Boards (Configuration Notes)". |
|
| Use the CABLUs (prefabricated cabling units) that are listed in the following table to establish the connection with the MDFU-E. Open-end cables must be used if an external patch panel is being used. See also Section 4.1.7 "Using an External Main Distribution Frame or External Patch Panel". |
CABLUs and open-end cables for SIVAPAC connectors |
|
| Information on cable and connector assignment is provided in the board descriptions in Chapter 3 "Boards for HiPath 3000". |
Closing the backplane of the system cabinets |
|
4.1.6.5 |
Connecting Peripherals to the Connector Panels with RJ45 Jacks |
| The boards should be installed in the cabinets as described in Section 4.1.5 "Installing Boards (Configuration Notes)". The connector panels plugged into the SIVAPAC connectors of the backplane are equipped with eight or 24 RJ45 jacks according to the relevant board. |
|
| Connect the peripheral directly to the 8-pin RJ45 jacks on the connector panels. |
|
| Information on cable and connector assignment is provided in the board descriptions in Chapter 3 "Boards for HiPath 3000". |
4.1.6.6 |
Connecting Peripherals to the Connector Panels with CHAMP Jack (for U.S. only) |
| The boards should be installed in the cabinets as described in Section 4.1.5 "Installing Boards (Configuration Notes)". The S30807-Q6626-X connector panels attached to the SIVAPAC connectors on the backplane are equipped with a CHAMP jack. |
|
| Connect the peripheral directly to the CHAMP jack in the connector panels. |
| |
| Information on cable and connector assignment is provided in the board descriptions in Chapter 3 "Boards for HiPath 3000". |
4.1.6.7 |
Connecting Peripherals to Connector Panels with SIPAC 1 SU Connectors |
| The boards should be installed in the cabinets as described in Section 4.1.5 "Installing Boards (Configuration Notes)". The S30807-Q6631-X connector panels attached to the SIVAPAC connectors on the backplane have two SIPAC 1 SU connectors each. |
|
| Use the CABLUs that are listed in the following table to establish the connection with the MDFU-E or an external patch panel. See also Section 4.1.7 "Using an External Main Distribution Frame or External Patch Panel". |
| In special cases where the prefabricated CABLUs cannot be used, open-end cables should be used. |
CABLUs and open-end cables for SIPAC 1 SU connectors |
|
| Information on cable and connector assignment is provided in the board descriptions in Chapter 3 "Boards for HiPath 3000". |