Safety Information for Australia (for Australia only) |
| • | Music on Hold and paging devices must be connected to the HiPath 3000 system via an ACA approved Line Isolation Unit. |
| • | HiPath 3550 and HiPath 3350 must be installed near the mains socket outlet, which is powering the system. The mains socket shall be readily accessible. Integrity of the main socket must be assured. |
| • | HiPath 3000 and HiPath 5000 may only be installed and maintained by authorized service personnel. |
| • | HiPath 3550 and HiPath 3350 must be earthed with a separate bonding earth, if the systems are powered by a UPS. |
| • | CE (customer equipment) does not continue to support emergency dialing after loss of mains power, if battery back up and power fail switchover to emergency analog phones is not available. |
| • | HiPath 3000/5000 must always be programmed to allow the dialing of emergency numbers (for example 000). |