Figures 
 
Figure 2-1 HiPath 3800 Dimensions
Figure 2-2 HiPath 3550 Dimensions
Figure 2-3 HiPath 3350 Dimensions
Figure 2-4 HiPath 3500 Dimensions
Figure 2-5 HiPath 3300 Dimensions
Figure 2-6 HiPath 5000 RSM Multi-Node IP System
Figure 2-7 Planning Load for HiPath 3000/5000 Systems
Figure 2-8 IP Trunking with TDM Terminal Points Only
Figure 2-9 IP Trunking and HFA Clients
Figure 2-10 IP Trunking and Node Connection via ISDN (PPP)
Figure 2-11 VPN Networking (Voice Only)
Figure 2-12 VPN Voice and Data, Home Office Connection
Figure 2-13 VPN Networking
Bild 2-14 IP terminals/clients for ISDN and ITSP connection in HiPath 3800
Figure 3-1 CBCC Board (S30810-Q2935-A401)
Figure 3-2 CBCC Board (S30810-Q2935-A301)
Figure 3-3 CBRC Board (S30810-Q2935-Z401)
Figure 3-4 CBRC Board (S30810-Q2935-Z301)
Figure 3-5 CBSAP Board (S30810-Q2314-X)
Figure 3-6 CBSAP - Front Panel
Figure 3-7 CMA with Spacing Bolts
Figure 3-8 Networking Options for HiPath 3000 Systems
Figure 3-9 CUC Backplane (S30777-Q750-X)
Figure 3-10 CUCR Backplane (S30777-Q750-Z)
Figure 3-11 CUP Backplane (S30777-Q751-X)
Figure 3-12 CUPR Backplane (S30777-Q751-Z)
Figure 3-13 DBSAP (S30807-Q6722-X)
Figure 3-14 DBSAP on the Backplane of the Expansion Cabinet
Figure 3-15 CBSAP with LIMS Module Plugged In
Figure 3-16 LUNA2 Front Panel
Figure 3-17 LUNA2 slots in the basic cabinet (outer panel mounted)
Figure 3-18 LUNA2 Slots in the Expansion Cabinet (With Outer Panel Mounted)
Figure 3-19 Rear View of the BSG 48/38 Battery Cabinet (S30122-K5950-F300)
Figure 3-20 Connections Between the BSG 48/38 Battery Cabinet and HiPath 3800
Figure 3-21 PSUP Interface (S30122-K5658-M)
Figure 3-22 HiPath 3800 - Connectors and Jacks on Backplane of Basic Cabinet
Figure 3-23 HiPath 3800 - Connectors and Jacks on Backplane of Expansion Cabinet
Figure 3-24 UPSC-D (S30122-K5660-M300)
Figure 3-25 UPSC-D (S30122-K5660-A300/-M300)
Figure 3-26 UPSC-D - Switches and LEDs
Figure 3-27 UPSC-D - Connectors
Figure 3-28 UPSC-DR (S30122-K7373-M900)
Figure 3-29 UPSC-DR (S30122-K7373-A900/-M900)
Figure 3-30 UPSC-DR - Switches and LEDs
Figure 3-31 UPSC-DR - Connectors
Figure 3-32 DIU2U (for U.S. only) Adapter Cable C39195-A7269-B625
Figure 3-33 DIU2U (for U.S. only) - Front Panel (S30810-Q2216-X)
Figure 3-34 DIUN2 - Front Panel (S30810-Q2196-X)
Bild 3-35 DIUT2 - Front panel (S30810-Q2226-X100)
Figure 3-36 HXGS3 (S30810-Q2943-X, S30810-Q2943-X1)
Figure 3-37 HXGR3 (S30810-K2943-Z)
Figure 3-38 HXGS3/HXGR3 - Interfaces
Figure 3-39 IVMNL, IVMN8 - Front Panel (S30122-H7688-X -X100)
Figure 3-40 IVMP4, IVMP4R
Figure 3-41 IVMP8 and IVMP8R (not for U.S.) - Packing Protection Covering
Figure 3-42 IVMP8, IVMP8R (S30122-Q7379-X100, -K7379-Z100) (not for U.S.)
Figure 3-43 IVMS8, IVMS8R - Packing Protection Covering
Figure 3-44 IVMS8, IVMS8R (S30122-Q7379-X, -K7379-Z)
Figure 3-45 IVMS8R - Front View (S30122-K7379-Z)
Figure 3-46 IVMS8N, IVMS8NR
Figure 3-47 PBXXX (S30810-Q6401-X) (for selected countries) - Front Panel
Figure 3-48 HiPath 3800 Basic Cabinet - 1x DIUN2 + 1 x PBXXX
Figure 3-49 PBXXX (for selected countries only) - Connecting the CAS Cable using the APPCU Adapter
Figure 3-50 PBXXX (for selected countries only) - Adapter Panel (C39165-A7050-C35)
Figure 3-51 HiPath 3800 Basic Cabinet - 1x DIUN2 + 2 x PBXXX
Figure 3-52 PBXXX (for selected countries only) - Connecting the CAS Cable using Two APPCU Adapters
Figure 3-53 SLA8N (not for U.S.), SLA16N, SLA24N (S30810-Q2929-X200, -X100, -X)
Figure 3-54 SLAD4, SLAD8 - interfaces
Figure 3-55 SLAD8R - interfaces
Figure 3-56 SLAD16 - Interfaces
Bild 3-57 SLAD16 - Einbau des Lüfterkits in HiPath 3550
Bild 3-58 SLAD16 - Anschlusskabel des Lüfterkits
Bild 3-59 SLAD16 - Anschluss des Lüfterkits
Figure 3-60 SLC16N (S30810-Q2193-X100) (not for U.S.)
Figure 3-61 Base Station Power Supply via One UP0/E Interface (not for U.S.)
Figure 3-62 Base Station Power Supply via Two UP0/E Interfaces (not for U.S.)
Figure 3-63 Base Station Power Supply via Three P0/E Interfaces (not for U.S.)
Figure 3-64 SLCN (not for U.S.) (S30810-Q2193-X300) - LEDs in the Front Panel
Figure 3-65 SLMAE8, SLMAE - Touch Guard
Figure 3-66 SLMAE8, SLMAE - LEDs on the Front Panel
Figure 3-67 SLMA/SLMA8 - LEDs on the Front Panel
Figure 3-68 SLMA2 (S30810-Q2246-X) (for selected countries only) - LEDs on the Front Panel
Bild 3-69 SLMAV8, SLMAV24
Bild 3-70 SLMAV8, SLMAV24 - LEDs in the front panel
Figure 3-71 SLMO2/SLMO8 - LEDs on the Front Panel
Figure 3-72 SLMO8 (not for U.S.), SLMO24 (S30810-Q2901-X100, S30810-Q2901-X)
Figure 3-73 SLU8 Interfaces (S30817-Q922-A301)
Figure 3-74 SLU8R Interfaces (S30817-K922-Z301)
Figure 3-75 STLS2 (not for U.S.), STLS4 Interfaces (S30817-Q924-B313, -A313)
Figure 3-76 Sample Pin Assignments in MW Jacks (not for U.S.)
Figure 3-77 Wiring and Ranges for S0 Bus Jacks (not for U.S.)
Figure 3-78 MWxx Jack Pin Assignment (for U.S. only)
Figure 3-79 STLS4R Interfaces (S30817-K924-Z313)
Figure 3-80 STLSX2, STLSX4, STLSX4R - Interfaces
Figure 3-81 Pin Assignments in MW Jacks
Figure 3-82 Wiring and Ranges for S0 Bus Jacks
Figure 3-83 STMD3 (S30810-Q2217-X10) - LEDs in the Front Panel
Figure 3-84 STMI2 (S30810-Q2316-X100) - HGA Slots
Figure 3-85 STMI2 - Front Panel
Figure 3-86 TCAS-2 (S30810-Q2945-X) (for selected countries only) - Figure
Figure 3-87 TCAS-2, TCASR-2 (for selected countries only) - Interfaces and Jumpers
Figure 3-88 TCAS-2, TCASR-2 (for selected countries only) - Connections
Figure 3-89 TCASR-2 (for selected countries only) - Front Panel
Figure 3-90 TCAS-2, TCASR-2 (for selected countries only) - CAS Application Software States
Figure 3-91 TCAS-2, TCASR-2 (for selected countries only) - Optional Modem
Figure 3-92 TCAS-2, TCASR-2 (for selected countries only) - Connection Options for Card Administration using CAS Manager
Figure 3-93 TCAS-2, TCASR-2 (for selected countries only) - RJ45 Cable C39195-Z7208-A10
Figure 3-94 TCAS-2, TCASR-2 (for selected countries only) - CAS Cable C39195-A7700-B13
Figure 3-95 TCAS-2, TCASR-2 (for selected countries only) - Impedance Converter F31505-E1-A146
Figure 3-96 CAS cable - shield contacting
Figure 3-97 TLA2, TLA4 (not for U.S.) - Interfaces (S30817-Q923-Bxxx, -Axxx)
Figure 3-98 TLA8 (not for U.S.) - Interfaces (S30817-Q926-Axxx)
Figure 3-99 TLA4R (not for U.S.) - Interfaces (S30817-Q923-Zxxx)
Figure 3-100 TM2LP - Front Panel (S30810-Q2159-Xxxx)
Figure 3-101 TMAMF (S30810-Q2587-Axxx)
Figure 3-102 Pin Assignments of the TMAMF Diagnostic Cable
Figure 3-103 TLANI2, TLANI4 - Interfaces (S30810-H2953-X1xx / -Xxx)
Figure 3-104 TLANI8 - Interfaces (S30810-H2954-X1xx)
Figure 3-105 TLANI4R - Interfaces (S30810-K2953-X2xx)
Bild 3-106 TMANI8 - front panel, LEDs (S30810-Q2327-Xxx)
Figure 3-107 TMC16 (for selected countries only) (S30810-Q2485-X) - Front Panel
Figure 3-108 TMCAS (S30810-Q2938-X)
Figure 3-109 TMCAS-2 (S30810-Q2946-X) (for selected countries only) - Figure
Figure 3-110 TMCAS-2 (for selected countries only) - Interfaces and Jumpers
Figure 3-111 TMCAS-2 (for selected countries only) - Front Panel
Figure 3-112 TMCAS-2 (for selected countries only) - CAS Application Software States
Figure 3-113 TMCAS-2 (for selected countries only) - Optional Modem
Figure 3-114 TMCAS-2 (for selected countries only) - Connection Options for Card Administration using CAS Manager
Figure 3-115 TMCAS-2 (for selected countries only) - CAS Cable C39195-A7700-B14
Figure 3-116 TMDID (for U.S. only) (S30810-Q2452-X) - Front Panel
Figure 3-117 TMDID2 (S30810-Q2197-T) (for selected countries only)
Figure 3-118 TMDID2 (for selected countries only) - LEDs on the Front Panel
Figure 3-119 E&M Interface Type 1A
Figure 3-120 E&M Interface Type 2
Figure 3-121 TMEW2 - Front Panel (S30810-Q2292-X100)
Figure 3-122 TMGL4 (for U.S. only) - Interfaces (S30810-Q2918-X)
Figure 3-123 TMGL4R (for U.S. only) (S30810-K2918-Z)
Figure 3-124 TMQ4 (for U.S. only) (S30810-Q2917-X)
Figure 3-125 TST1 (for U.S. only) (S30810-Q2919-X/S30810-K2919-Z)
Figure 3-126 TS2 (not for U.S.) - Interfaces (S30810-Q2913-X100, -X300)
Figure 3-127 TS2R (not for U.S.) - Interfaces (S30810-K2913-Z100, -Z300)
Figure 3-128 S2M Trunk Connection
Figure 3-129 S2M - NT Connections for Spain and Portugal
Figure 3-130 4SLA (not for U.S.), 8SLA - Interfaces (S30810-Q2923-X200, -X100)
Figure 3-131 16SLA (not for U.S.) - Interfaces (S30810-Q2923-X)
Figure 3-132 8SLAR Interfaces (S30810-K2925-Z)
Figure 3-133 ALUM4 - Function
Figure 3-134 ALUM4 - Interfaces (S30817-Q935-A)
Figure 3-135 ALUM4 - Basic Structure
Figure 3-136 AMOM - Connection to DIUN2, DIU2U, and DIUT2
Figure 3-137 ANI4 (for selected countries only) - Interfaces (S30807-Q6917-Axxx)
Figure 3-138 ANI4 (for selected countries only) - Installation Steps
Figure 3-139 ANI4R (for selected countries only) (S30807-Q6917-Z103)
Figure 3-140 EXM Slot for HiPath 3550 and HiPath 3350 Wall Housing
Figure 3-141 EXMR connection to HiPath 3550 and HiPath 3350
Figure 3-142 EXMR Connection to HiPath 3500 and HiPath 3300
Figure 3-143 EVM (S30807-Q6945-X) - Interfaces
Figure 3-144 EXMNA (for U.S. only) (S30807-Q6923-X)
Figure 3-145 EXMNA (for U.S. only) - Slot for HiPath 3550 and HiPath 3350
Figure 3-146 GEE12, GEE16, GEE50 (not for U.S.) - Interfaces (S30817-Q951-Axxx)
Figure 3-147 HOPE (for U.S. only) (S30122-Q7078-X; S30122-Q7079-X)
Figure 3-148 OPAL (C39195-A7001-B130)
Figure 3-149 OPALR (C39195-A7001-B142)
Figure 3-150 ALUM Using PFT1/PFT4 (not for U.S.)
Figure 3-151 Installation Location of PFT1 and PFT4 (MDFU/MDFU-E) (not for U.S.)
Figure 3-152 PFT1 (S30777-Q539-X) and PFT4 (S30777-Q540-X) Board Assignment
Figure 3-153 REALS (S30807-Q6629-X)
Figure 3-154 REALS Slots in the Basic Cabinet (With Outer Panel Mounted)
Figure 3-155 STBG4 (for France only) - Interfaces (S30817-Q934-A)
Figure 3-156 STRB Interfaces (S30817-Q932-A)
Figure 3-157 STRBR Interfaces (S30817-Q932-Z)
Figure 3-158 STRB and STRBR Board Relay and Sensor Functions
Figure 3-159 V24/1 (not for U.S.) (S30807-Q6916-X100)
Figure 3-160 HiPath 3550 and HiPath 3350 - V.24 Connections
Figure 3-161 V.24 (RS-232) Connector Assignment, HiPath 3550 and HiPath 3350
Figure 3-162 V.24 Cable Assignment (C30267-Z355-A25)
Figure 4-1 HiPath 3800 - Setting Up the Basic Cabinet
Figure 4-2 HiPath 3800 - Positioning the Cabinet Feet
Figure 4-3 HiPath 3800 - Installing a Stacked Two-Cabinet System (Rear View)
Figure 4-4 HiPath 3800 - Installing a Two-Cabinet System Side by Side (Rear View)
Figure 4-5 HiPath 3800 - Grounding the System Cabinets and Main Distribution Frame (nor for U.S.)
Figure 4-6 HiPath 3800 - Grounding Option 1a (not for USA)
Figure 4-7 HiPath 3800 - Grounding Option 1b (not for USA)
Figure 4-8 HiPath 3800 - Earth ground connection (for U.S. only)
Figure 4-9 HiPath 3800 - System Cabinet with Plastic Cover
Figure 4-10 HiPath 3800 - Installation Examples in the 19-Inch Cabinet
Figure 4-11 HiPath 3800 - Removing Cabinet Feet
Figure 4-12 HiPath 3800 - Installing System Cabinets in 19-Inch Cabinet
Figure 4-13 HiPath 3800- Grounding the Systems and Patch Panels in a 19-Inch Cabinet
Figure 4-14 HiPath 3800 - Board Slots in the Basic Cabinet
Figure 4-15 HiPath 3800 - Board Slots in the Expansion Cabinet
Figure 4-16 HiPath 3800 - Removing/Inserting the Board Using the Board Wrench
Figure 4-17 Installing the Board Shielding Cover
Figure 4-18 HiPath 3800 - Installing the LUNA2 Power Supply Unit
Figure 4-19 HiPath 3800 - Slots for LUNA2 and REALS in the Basic Cabinet (With Outer Panel Mounted)
Figure 4-20 HiPath 3800 - Slots for LUNA2 in the Expansion Cabinet (With Outer Panel Mounted)
Figure 4-21 HiPath 3800 - Installing the REALS Board
Figure 4-22 SIVAPAC-SIPAC Board Adapter
Figure 4-23 Installing the SIVAPAC-SIPAC Board Adapter
Figure 4-24 Replacing the Board Lock
Figure 4-25 HiPath 3800 - Initialization of Subscriber Line Circuits and Ports
Figure 4-26 HiPath 3800 - PCM Highways in the Basic Cabinet
Figure 4-27 HiPath 3800 - PCM Highways in the Expansion Cabinet
Figure 4-28 HiPath 3800 - Backplane (S30804-Q5392-X) of the Basic Cabinet
Figure 4-29 HiPath 3800 - Connectors and Jacks on the Backplane of the Basic Cabinet
Figure 4-30 HiPath 3800 - Expansion Cabinet Backplane (S30804-Q5393-X)
Figure 4-31 HiPath 3800 - Connectors and Jacks on the Backplane of the Expansion Cabinet
Figure 4-32 HiPath 3800 - Backplane of the Basic Cabinet with Mounted Filler Panels
Figure 4-33 HiPath 3800 - connector panels with RJ45 Jacks
Figure 4-34 HiPath 3800 - Connector Panel with CHAMP Jack (for U.S. only)
Figure 4-35 HiPath 3800 - Connector Panel with Two SIPAC 1 SU Connectors (S30807-Q6631-X)
Figure 4-36 MDFU-E - Layout and Dimensions (669.0 x 328.8 x 125.4 mm)
Figure 4-37 Assignment (Numbering) of the Splitting/Jumper Strips (view from above)
Figure 4-38 Stripping an Open-End Cable for the MDFU-E
Figure 4-39 Patch Panel S30807-K6143-X
Figure 4-40 Installing the External Patch Panel in the 19-Inch Cabinet
Figure 4-41 Layout of the Patch Panel S30807-K6143-X for Different Peripheral Boards
Figure 4-42 Assignment of Patch Panel S30807-K6143-X
Figure 4-43 S0 Patch Panel C39104-Z7001-B3
Figure 4-44 Installing the External S0 Patch Panel in the 19-Inch Cabinet
Figure 4-45 Assignment of the S0 Patch Panel C39104-Z7001-B3
Figure 4-46 Laying Wire Pairs at the S0 Patch Panel
Figure 4-47 Stripping the Open-End Cable for the S0 Patch Panel
Bild 4-48 HiPath 3550 and HiPath 3350 - Space Requirements
Figure 4-49 MDFU - Layout and Dimensions (367.0 x 328.8 x 125.4 mm) (not for U.S.)
Figure 4-50 HiPath 3550 and HiPath 3350 - Wall Attachment
Figure 4-51 HiPath 3550 and HiPath 3350 - Wall Attachment
Figure 4-52 HiPath 3550, HiPath 3350 - Grounding an External Main Distribution Frame
Figure 4-53 Layout of CABLU S30269-Z41-A30 (Length = 3 m)
Figure 4-54 HiPath 3550 - Backplane port for peripheral board
Figure 4-55 Integrated Distribution Frame - Slip-On Connector Screw Connections
Figure 4-56 HiPath 3550 and HiPath 3350 - Power Cable with Ferrite Sleeve
Figure 4-57 HiPath 3550 - Wall Housing System Overview
Figure 4-58 HiPath 3550 - Slots in the Wall Housing
Figure 4-59 HiPath 3550 - Option Adapter Long (OPAL)
Figure 4-60 HiPath 3350 - Wall Housing System Overview
Figure 4-61 HiPath 3350 - Slots in the Wall Housing
Figure 4-62 HiPath 3500 and HiPath 3300 - Wall Installation (for U.S.)
Figure 4-63 HiPath 3500 and HiPath 3300 - Mounting the 19-Inch Cabinet
Figure 4-64 HiPath 3500 and HiPath 3300 - Grounding
Figure 4-65 HiPath 3500 and HiPath 3300 - Connection Cable for PB3000
Figure 4-66 HiPath 3500 - Slot Levels in the 19-Inch Housing
Figure 4-67 HiPath 3300 - Slot Levels in the 19-Inch Housing
Figure 6-1 HiPath 5000 RSM Multi-Node IP System
Figure 6-2 Customer Data Exchange Between the Feature Server and Nodes
Figure 6-3 Feature Server Services and Routines
Figure 6-4 P 500 UPS - Front and Rear Panel
Figure 8-1 Licensing Process with Central License Server (CLS)
Figure 8-2 Distribution of Licenses with HiPath 3000/5000 Manager E
Figure 8-3 Procedure for Licensing optiClient Attendant V8 on HiPath 3000 V8
Fig. 9-1 Sample Connection of a CDR Printer to HiPath 3000
Fig. 9-2 Front Panel of the PB3000
Fig. 9-3 Back of the PB3000
Fig. 9-4 PB3000 with batteries and LUNA2
Fig. 9-5 PB300 with Batteries - Block Diagram
Fig. 9-6 PB3000 with Batteries and LUNA2 - Block Diagram
Fig. 9-7 Connection Options for Entrance Telephones
Fig. 9-8 Direct Connection of Entrance Telephones
Fig. 9-9 Connecting DoorCom Analog to HiPath 3000
Fig. 9-10 Connecting Speakers to an Analog Station Port
Fig. 9-11 Connecting Speakers to an Analog Trunk Port
Fig. 9-12 Configuration differences between V4.0 and V5.0 or later
Fig. 9-13 CDB Conversion From V4.0 to V5.0 or Later (Part 1 of 4)
Fig. 9-14 CDB Conversion From V4.0 to V5.0 or Later (Part 2 of 4)
Fig. 9-15 CDB Conversion From V4.0 to V5.0 or Later (Part 3 of 4)
Fig. 9-16 CDB Conversion From V4.0 to V5.0 or Later (Part 4 of 4)
Fig. 10-1 OpenStage 10
Fig. 10-2 OpenStage 15
Fig. 10-3 OpenStage 20
Bild 10-4 OpenStage 30
Bild 10-5 OpenStage 40
Fig. 10-6 OpenStage 60
Figure 10-7 OpenStage 80 [CorNet-IP (HFA)]
Bild 10-8 OpenStage 15 (CorNet IP) - Underside of the Telephone
Bild 10-9 OpenStage 20, OpenStage 40 (CorNet IP) - Underside of the Telephone
Bild 10-10 OpenStage 60, OpenStage 80 (CorNet IP) - Underside of the Telephone
Bild 10-11 OpenStage 10 T, OpenStage 20 T - Underside of the Telephone
Bild 10-12 OpenStage 15 T - Underside of the Telephone
Bild 10-13 OpenStage 30 T, OpenStage 40 T - Underside of the Telephone
Bild 10-14 OpenStage 60 T, OpenStage 80 T - Underside of the Telephone
Bild 10-15 OpenStage Key Module 15
Bild 10-16 OpenStage Key Module
Bild 10-17 OpenStage BLF
Fig. 10-18 OpenStage (CorNet-IP) - Connection of the External Power Supply Unit
Fig. 10-19 OpenStage (TDM) - Connection of the External Power Supply Unit
Fig. 10-20 OpenStage PhoneAdapter
Fig. 10-21 Western-Modular jack (RJ12)
Fig. 10-22 Headsets
Fig. 10-23 optiPoint 410 entry, 410 entry S - Standard Key Assignment
Fig. 10-24 optiPoint 410 economy, 410 economy S - Standard Key Assignment
Fig. 10-25 optiPoint 410 economy plus, 410 economy plus S - Standard Key Assignment
Fig. 10-26 optiPoint 410 standard, 410 standard S - Standard Key Assignment
Fig. 10-27 optiPoint 410 advance, 410 advance S - Standard Key Assignment
Fig. 10-28 optiPoint 420 economy, 420 economy S - Standard Key Assignment
Fig. 10-29 optiPoint 420 economy plus, economy plus S - Standard Key Assignment
Fig. 10-30 optiPoint 420 standard, 420 standard S - Standard Key Assignment
Fig. 10-31 optiPoint 420 advance, 420 advance S - Standard Key Assignment
Fig. 10-32 optiPoint 410, 420, 410 S, 420 S - Connection Options
Figure 10-33 optiPoint self labeling key module
Fig. 10-34 optiPoint 410 display module
Fig. 10-35 optiPoint 600 office - Default Key Assignment
Fig. 10-36 optiPoint 500 entry - Standard Key Assignment (Default)
Fig. 10-37 optiPoint 500 economy (not for U.S.) Standard Key Layout
Fig. 10-38 optiPoint 500 basic - Standard Key Assignment (Default)
Fig. 10-39 optiPoint 500 standard - Standard Key Assignment (Default)
Fig. 10-40 optiPoint 500 advance - Standard Key Assignment (Default)
Fig. 10-41 optiPoint 500 Connection Options
Fig. 10-42 optiPoint key module
Fig. 10-43 optiPoint BLF
Fig. 10-44 optiPoint 500 Option Bays
Fig. 10-45 optiPoint analog adapter
Fig. 10-46 optiPoint ISDN adapter
Fig. 10-47 optiPoint phone adapter
Fig. 10-48 Example a Host-Client Configuration
Fig. 10-49 optiPoint acoustic adapter
Fig. 10-50 Y Cable for optiPoint acoustic adapter
Fig. 10-51 optiPoint recorder adapter
Fig. 10-52 optiLog 4me
Fig. 10-53 Example: External AC Adapter Connection
Fig. 10-54 Example: Corded and Cordless Headsets
Fig. 10-55 HiPath AP 1120
Figure 10-56 optiPoint WL2 professional
Fig. 10-57 optiPoint 500 standard: Standard Key LayoutoptiPoint Attendant
Figure 10-58 Gigaset SL3 professional
Figure 10-59 Gigaset S4 professional
Figure 10-60 Gigaset M2 professional
Figure 11-1 BS3/1 S30807-H5482-X Base Station
Figure 11-2 BS3/1 (BS3/S) and BS3/3 in the Outdoor Cover S30122-X7469-X
Figure 11-3 Example of a Cordless Extension Connection in Networked Systems
Figure 11-4 Incorrect DECT Configuration of Networked HiPath 3000 Systems
Figure 11-5 Correct DECT Configuration when Networking HiPath 3000 Systems
Figure 11-6 Correct DECT Configuration when Networking HiPath 3000 Systems
Figure 12-1 Trace Monitor
Figure 12-2 The Screen Layout of the Trace Monitor
Figure 12-3 Example of Remote Service with HiPath 3000