3.3.42  

TMEW2 
 
NOTE: Danger of damage to property due to surge voltage. The required lightning protection measures must be taken for this board, see Section 2.1.2 "Lightning Protection".  

Introduction  
The TMEW2 board (Trunk Module for E&M World) provides four analog tie trunk circuits for E&M signaling for HiPath 3800. Each tie trunk circuit has eight connectors: incoming speech path (2), outgoing speech path (2), incoming signaling (2) and outgoing signaling (2). This allows tie trunk traffic to other private communication systems.
Interface types 1A and 5 are released for E&M networking with the Immediate Start, Wink Start, and Delay Dial protocols. Interface types 1A and 5 are identical.
The peripheral board slots on the HiPath 3800 are fitted with SIPAC 9 SU connectors. Since the TMEW2 board has SIVAPAC connector strips, you will have to install a SIVAPAC-SIPAC board adapter in order to be able to use it in HiPath 3800.  
For information on this procedure, please see Section 4.1.6.6 "Connecting Peripherals to the Connector Panels with CHAMP Jack (for U.S. only)".  

Note on E&M networking compatibility  
TMEW2 does not support E&M interface types 1, 1B, 2 and 3 on the TIEL board.
The following options are available when replacing a HiPath 3750 or HiPath 3700 system with a HiPath 3800 system:
   1.   Switch customer-specific E&M networking to interface type 1A (or 5) on the TMEW5 board (Immediate Start, Wink Start or Delay Dial protocols).
   2.   If option 1 is not possible for technical reasons, HiPath 3750 or HiPath 3700 remains active as the E&M gateway. Create a TDM network with the CorNet protocol between the HiPath 3750 or HiPath 3700 system and HiPath 3800.

Speech paths  
Speech paths always use four wires (two wires for the incoming speech path and two wires for the outgoing speech path). The advantage of providing separate speech paths for incoming and outgoing calls is that it helps maintain call stability (echo). In addition, repeaters in the transmission equipment compensate for attenuation loss on the line.

Signaling paths  
E&M trunks are used for signaling between networked communications systems: E-wire = ear (receive), M-wire = mouth (transmit).

Protocol settings  
TMEW2 supports interface types 1A and 5. Interface types 1A and 5 are identical.
Before starting up the tie trunk, you must ensure that the two participating systems support the specified interface types.
 Figure 3-119   E&M Interface Type 1A
 
The following signaling protocols are supported:
 •   "Delay Dial" protocol
 •   "Wink Start" protocol
This is the most widely used protocol internationally.
 •   "Immediate Start" protocol
HiPath 3000/5000 Manager E is used to set the signaling protocol. Go to the Settings menu and select Lines/networking -> Trunks -> (double-click) Parameters -> Template Editor:
 •   Board type = TMDID, TIEL, TMEW2
 •   Template: the following settings are possible:
   -   4. E/M tieline with winkstart/delayed (= "Wink Start" protocol)
   -   11. E/M tieline with delayed dialing (= "Delay Dial" protocol)
   -   12. E/M tieline with immediate dialing (= "Immediate Start" protocol)
    Interface type 1A (or 5) is used in all cases.
SIVAPAC connector assignment on the backplane with tie trunk traffic via interface type 1A (or 5) is shown in Tabelle 3-165.

Connecting the Genius announcement device  
The TMEW2 board may be installed on interface type 2 for connecting the Genius announcement device.
 Figure 3-120   E&M Interface Type 2
 
Use HiPath 3000/5000 Manager E to configure the settings for the Genius announcement device: Go to the Settings menu and select Auxiliary equipment -> Announcement.
SIVAPAC connector assignment on the backplane with a Genius announcement device connected (interface type 2A) is shown in Table 3-166.

Front panel  
 Figure 3-121   TMEW2 - Front Panel (S30810-Q2292-X100)
 
To ensure sufficient shielding, provide the board with a shielding panel. For information on mounting the shielding panel, see Section 4.1.5.3 "Inserting or Removing Boards".  

LED statuses and their meanings  

 Table 3-164   TMEW2 - LED Statuses
 Red LED  
 Green LED  
 Status  
 Action  
 Off  
 Off  
Board not receiving power or not plugged in correctly.  
Board is out of order.  
Check plug contact on board.  
 On  
 Off  
Board is receiving power and board test is in progress.  
Board is defective if status remains unchanged (board test unsuccessful).  
 
 
Replace the board.  
Loadware loading not successfully completed. Board is faulty.  
Replace the board.  
Error detected on board.  
Board is deactivated (not applicable to errors detected by test loops) or board was deactivated using HiPath 3000/5000 Manager E.  
Check whether the board was deactivated using HiPath 3000/5000 Manager E. If not, replace board.  
 Flashing  
 Off  
Loadware is being loaded.  
 
 Off  
 On  
Board test completed successfully. Board is OK (idle state).  
 
 Off  
 Flashing  
At least one subscriber line circuit is activated.  
 

Cable and connector assignment  
SIVAPAC connector assignment on the backplane depends on how the board is used.
 •   Assignment in the case of tie trunk traffic via interface type 1A (or 5): Tabelle 3-165.
 •   Assignment in the case of Genius announcement device connection (interface type 2): Table 3-166.

 Tabelle 3-165   TMEW2 - SIVAPAC Connector Assignment on the Backplane in Tie Trunk Traffic via Interface Type 1A (or 5)
 Pair  
 a-wire1 (tip)  
 b-wire1 (ring)  
 SIVAPAC connector  
 TMEW2  
 MDFU-E  
 Notes  
 1  
 wht/blu  
   
 1  
 1ka  
 Port 1  
 1a  
 Ring  
Transmit  
   
 blu/wht  
 23  
 1kb  
 1b  
 Tip  
 2  
 wht/ora  
   
 3  
 1ka  
 Port 2  
 2a  
 Ring  
Transmit  
   
 ora/wht  
 4  
 1kb  
 2b  
 Tip  
 3  
 wht/grn  
   
 5  
 1ka  
 Port 3  
 3a  
 Ring  
Transmit  
   
 grn/wht  
 6  
 1kb  
 3b  
 Tip  
 4  
 wht/brn  
   
 7  
 1ka  
 Port 4  
 4a  
 Ring  
Transmit  
   
 brn/wht  
 8  
 1kb  
 4b  
 Tip  
 5  
 wht/gry  
   
 9  
 1ga  
 Port 1  
 5a  
 Ring  
Receive  
   
 gry/wht  
 10  
 1gb  
 5b  
 Tip  
 6  
 red/blu  
   
 11  
 1ga  
 Port 2  
 6a  
 Ring  
Receive  
   
 blu/red  
 12  
 1gb  
 6b  
 Tip  
 7  
 red/ora  
   
 13  
 1ga  
 Port 3  
 7a  
 Ring  
Receive  
   
 ora/red  
 14  
 1gb  
 7b  
 Tip  
 8  
 red/grn  
   
 15  
 1ga  
 Port 4  
 8a  
 Ring  
Receive  
   
 grn/red  
 16  
 1gb  
 8b  
 Tip  
 9  
 red/brn  
   
 17  
 1E  
 Port 1  
 9a  
 Ear  
 
   
 brn/red  
 18  
 1M  
 9b  
 Mouth  
 10  
 red/gry  
   
 19  
 1E  
 Port 2  
 10a  
 Ear  
 
   
 gry/red  
 20  
 1M  
 10b  
 Mouth  
 11  
 blk/blu  
   
 24  
 1E  
 Port 3  
 11a  
 Ear  
 
   
 blu/blk  
 25  
 1M  
 11b  
 Mouth  
 12  
 blk/ora  
   
 26  
 1E  
 Port 4  
 12a  
 Ear  
 
   
 ora/blk  
 27  
 1M  
 12b  
 Mouth  
 13  
 blk/grn  
   
 29  
   
 Port 1  
 13a  
System ground, system battery  
   
 grn/blk  
 30  
   
 13b  
 14  
 blk/brn  
   
 31  
   
 Port 2  
 14a  
System ground, system battery  
   
 brn/blk  
 32  
   
 14b  
 15  
 blk/gry  
   
 34  
   
 Port 3  
 15a  
System ground, system battery  
   
 gry/blk  
 35  
   
 15b  
 16  
 yel/blu  
   
 37  
   
 Port 4  
 16a  
System ground, system battery  
   
 blu/yel  
 38  
   
 16b  
1see "Abbreviations for colors" at the start of Section 3.3 "Peripheral Boards".

 Table 3-166   TMEW2 - SIVAPAC Connector Assignment on the Backplane with Genius Announcement Device Connected (Interface Type 2):
 Pair  
 a-wire1 (tip)  
 b-wire1 (ring)  
 SIVAPAC connector  
 TMEW2  
 MDFU-E  
 Notes  
 1  
 wht/blu  
   
 1  
 1ka  
 Port 1  
 1a  
 Ring  
Transmit  
   
 blu/wht  
 23  
 1kb  
 1b  
 Tip  
 2  
 wht/ora  
   
 3  
 1ka  
 Port 2  
 2a  
 Ring  
Transmit  
   
 ora/wht  
 4  
 1kb  
 2b  
 Tip  
 3  
 wht/grn  
   
 5  
 1ka  
 Port 3  
 3a  
 Ring  
Transmit  
   
 grn/wht  
 6  
 1kb  
 3b  
 Tip  
 4  
 wht/brn  
   
 7  
 1ka  
 Port 4  
 4a  
 Ring  
Transmit  
   
 brn/wht  
 8  
 1kb  
 4b  
 Tip  
 5  
 wht/gry  
   
 9  
 1ga  
 Port 1  
 5a  
 
Free  
   
 gry/wht  
 10  
 1gb  
 5b  
 6  
 red/blu  
   
 11  
 1ga  
 Port 2  
 6a  
 
Free  
   
 blu/red  
 12  
 1gb  
 6b  
 7  
 red/ora  
   
 13  
 1ga  
 Port 3  
 7a  
 
Free  
   
 ora/red  
 14  
 1gb  
 7b  
 8  
 red/grn  
   
 15  
 1ga  
 Port 4  
 8a  
 
Free  
   
 grn/red  
 16  
 1gb  
 8b  
 9  
 red/brn  
   
 17  
 1E  
 Port 1  
 9a  
 Ear  
   
 brn/red  
 18  
 1M  
 9b  
 System ground  
 10  
 red/gry  
   
 19  
 1E  
 Port 2  
 10a  
 Ear  
   
 gry/red  
 20  
 1M  
 10b  
 System ground  
 11  
 blk/blu  
   
 24  
 1E  
 Port 3  
 11a  
 Ear  
   
 blu/blk  
 25  
 1M  
 11b  
 System ground  
 12  
 blk/ora  
   
 26  
 1E  
 Port 4  
 12a  
 Ear  
   
 ora/blk  
 27  
 1M  
 12b  
 System ground  
 13  
 blk/grn  
   
 29  
   
 Port 1  
 13a  
 Mouth  
   
 grn/blk  
 30  
   
 13b  
 System battery  
 14  
 blk/brn  
   
 31  
   
 Port 2  
 14a  
 Mouth  
   
 brn/blk  
 32  
   
 14b  
 System battery  
 15  
 blk/gry  
   
 34  
   
 Port 3  
 15a  
 Mouth  
   
 gry/blk  
 35  
   
 15b  
 System battery  
 16  
 yel/blu  
   
 37  
   
 Port 4  
 16a  
 Mouth  
   
 blu/yel  
 38  
   
 16b  
 System battery  
1see "Abbreviations for colors" at the start of Section 3.3 "Peripheral Boards".