3.3.9  

IVMS8N, IVMS8NR 
 

Introduction  
The following boards are used for the integrated voice mail functionality in HiPath Xpressions Compact in V2.5 and later:
 •   IVMS8N (Integrated Voice Mail Small New) S30122-Q7379-X200 - for HiPath 3550 and HiPath 3350 (wall housing)
 •   IVMS8NR (Integrated Voice Mail Small New Rack) S30122-K7379-Z200 - for HiPath 3500 and HiPath 3300 (19-inch housing)
Up to 500 mailboxes are available with a total storage capacity of 100 hours. The boards can also be used for Music on Hold and announcements.
HiPath Xpressions Compact supports a central voice mail functionality in a
HiPath 3000/5000 network. All stations can use the central voice mail server.  
HiPath Xpressions Compact may be used as a central announcement device in a network system with V6.0 SMR-06 or later.  
Optional administration of HiPath Xpressions Compact is also possible via the board's Ethernet (10/100BaseT) interface.
Only one IVMS8N or IVMS8NR may be installed per system.  
For thermal reasons, the IVMS8N board may only be used in slots 5, 7, and 9 (lower slots) in HiPath 3550 (wall housing).  
Slot 5 can only be used for the IVMS8N board in HiPath 3350 (wall housing).  
For detailed information on HiPath Xpressions Compact, startup and administration, see the manual for the product.

Packing protection covering  
You must remove the red packing protection covering (cardboard block) before starting up the board.
If it is necessary to transport the board again at a later time, for example, for servicing, you must reattach the packing protection covering.

Switches and LEDs  
 Figure 3-46   IVMS8N, IVMS8NR
 

Lockout switch settings  
 •   Pressed = free (default)
 •   Not pressed = locked: existing connections remain active, new connections are locked.
   -   The yellow LED lights up when all connections are ended and the board is effectively locked.
   -   The yellow LED flashes when a lockout request is entered (via lockout switch or software) but at least one call is still active.
To reset the board to the default state, activate the lockout switch twice within the first 10 s of board startup.

Assignment of the RJ45 jack X3  
The Ethernet (10/100BaseT) interface is accessed via the 8-pin RJ45 jack X3.

 Table 3-50   IVMS8N, IVMS8NR - Assignment of the RJ45 Jack X3 (LAN Connector)
 RJ45 Jack X3  
 Pin  
 Signal  
 Description  
 1  
 Tx +  
Transmit +  
 2  
 Tx -  
Transmit -  
 3  
 Rx +  
Receive +  
 4  
 -  
Not used  
 5  
 -  
Not used  
 6  
 Rx -  
Receive -  
 7  
 -  
Not used  
 8  
 -  
Not used  

LED statuses and their meanings  

 Table 3-51   IVMS8N, IVMS8NR - LED Statuses
 LED
Yellow  
 LED
Green  
 Meaning  
 Action  
During Startup and Initialization  
 Off  
 Off  
 1  
Boot procedure (lasts approx. 60 s)  
 
 On  
 On  
 2  
LED test (lasts approx. 10 s)  
 
 On  
 Off  
 3  
Lockout switch state signaling by yellow LED (lasts approx. 5 s):  
 •   blocked = On
 •   free = Off
Possibly check if board was deactivated using
HiPath 3000/5000 Manager E or lockout switch.  
 Off  
 Flashing
(500/500 ms)  
 Off  
 4  
Hard disk test, application startup (depending on hard disk status, lasts approx. 2 - 9 minutes)  
 
 Off  
 On  
 5a  
Standby mode after successful boot  
 
 On  
 Off  
 5b  
Board locked or board error occurred  
Check whether board was deactivated using HiPath 3000/5000 Manager E or lockout switch.  
Change board if faulty.  
During Operation  
 Off  
 On  
Idle (no call)  
 
 Flashing
(500/500 ms)  
 Off  
At least one active port (call)  
 
 Flashing
(500/500 ms)  
 Flashing
(500/500 ms)  
Lockout switch activated during a call  
 
 On  
 Off  
Board locked or board error occurred  
Check whether board was deactivated using HiPath 3000/5000 Manager E or lockout switch.  
Change board if faulty.  
 Flashing
(100/100 ms)  
 Off  
Upgrade process active