3.2.11  

LIMS 
 
Caution  
The LIMS module must not be plugged in or out when the system is energized.  

Introduction  
The LAN Interface Module for SAPP LIMS (S30807-Q6721-X) is an optional plug-in card for the CBSAP central control board in HiPath 3800.
The board provides two Ethernet (10BaseT) LAN connectors via two 8-pin RJ45 jacks:
 •   LAN1 (administration via HiPath 3000/5000 Manager E and CTI functions)
 •   LAN2 (not assigned)
The LIMS module can be used for administration via HiPath 3000/5000 Manager E and for CTI functions (TAPI 120 V2.0). However, bear in mind that the number of BHCAs (Busy Hour Call Attempts = number of connection attempts during busy traffic hours) is restricted to 400 at a maximum of six TAPI ports. The use of "power dialers" is not approved.
In V6.0 or later, the system software deactivates an existing LIMS module when an STMI2 board is inserted. You cannot operate the LIMS module and an STMI2 board simultaneously in a HiPath 3800.
 Figure 3-15   CBSAP with LIMS Module Plugged In
 

RJ45 jack assignment  

 Table 3-21   LIMS - RJ45 Jack Assignment
 Pin  
 Signal  
 Description  
 1  
 Tx +  
Transmit +  
 2  
 Tx -  
Transmit -  
 3  
 Rx +  
Receive +  
 4  
 -  
Not used  
 5  
 -  
Not used  
 6  
 Rx -  
Receive -  
 7  
 -  
Not used  
 8  
 -  
Not used