9.4.12 |
PRI (US only) |
Slot / port field |
| Here you can select the slot / port of a PRI card. |
Protocol field |
| In this field the adjusted protocol is shown. |
Frame / Line / Encode field |
| Here it can be selected the Layer 1 parameters for physical encoding of the line. There are only two choices, because it is not allowed to mix the parameters. Most new lines support ESF (Extended Superframe Mode) with a max. data throughout of 64 kbit / sec. |
| Older equipment and some special installations work in SF (Superframe Mode) with a max. data throughout of 56 kbit / sec. |
| ISDN provider informs customer whether or not a line can operate in ESF mode. |
| The meanings of the other abbreviations are the encoding type (B8ZS: Bipolar 8 Zero Substitution or ZCZ: Zero Code Suppression) and the D - channel encoding (normal or inverted). |
B-channels field |
| Here is shown the used number of B-channels. |
Inwats Duwa field |
| Dependent on a trunk group an INWATS DNIS (Dialed Number Identification Service) port is assigned to a DID port. This DID port should be configured as a pseudo port, this means that it is locked for basic DID. The entries in the CM tables are valid for the INWATS DNIS port. |
CBC-trunk group field and CBC-pool field |
| These fields allow to install a CBC-pool. One CBC-pool can exist of up to eight services. In the field CBC-trunk group the different CBC-access codes can be configured. In the field CBC-pool the according service can be configured. |
|
| HiPath 3000/5000 V8, Manager E, Administrator Documentation, Issue 10 | up ![]() |
|
![]() |
||
| Disclaimer & Copyright | ID: P31003H3580M1000176A9 | 2011-01-24 |