9.2.7 |
Emergency |
| Emergency enables you to control the behavior of the IP Workpoint clients (system clients) within the framework of the SRS concept ( Small Remote Sites). A detailed description of the SRS concept can be found in the manual " HiPath 3000/5000, Feature Description". |
Small remote sites redundancy |
| Activate this flag if the SRS concept is to be used. |
Emergency text |
| Enter the text (max. 15 characters) to be displayed on the system clients in the event of an emergency (failure of the HiPath 4000) here. |
Workpoint Clients table |
| The table shows all the system clients that have been set up. |
Call No. column |
| The internal call number of each station is shown here. |
Name column |
| The name assigned to the station is shown here. |
CFSS-Destination column |
| You can select a forwarding destination for each station via the drop-down list. If the system client is not working (e.g. because the PC on which OpenScape Personal Edition is running has been shut down), calls will be forwarded to the specified destination. |
| The local call number may not be entered as a target. If a station with the same call number is entered as a CFSS target in another system, this call number must be unique within the system. It should not conflict with the internal dial plan. A call number of this type must then be assigned a prefix (or seizure code) that is configured in the LCR dial plan. |
Emergency text column |
| For each system client you can specify here whether the text entered in the Emergency Text field should be shown on its display in the event of an emergency. The Emergency text for all button can be used to enable or disable the option for all system clients. |
Manual Switchback column |
| Under normal circumstances, the system client automatically registers back at the HiPath 4000 as soon as it detects that the HiPath 4000 can be reached again. |
| If the Manual Switchback option is set, and the CDB is being copied back to the communication system, the terminals are forced to immediately switch back to their main system. The switchback occurs independently of the call state. |
"Emergency text for all" button |
| Click this button to enable or disable the option in the Emergency text column for all system clients. |
"Manual Switchback for all" button |
| Click this button to enable or disable the option in the Manual Switchback column for all system clients. |
| |
| HiPath 3000/5000 V8, Manager E, Administrator Documentation, Issue 10 | up ![]() |
|
![]() |
||