9.2.1 |
Subscriber |
| The Station tab consists of a table, which is divided into the following columns. The values for the call number, DID number and name can be changed by selecting the individual fields. |
| The table is often not fully visible. In order to see all entries, use the horizontal scroll function or reduce the width of the columns by moving the column separators. |
| This station status can also be printed via Print / Print Preview. |
|
Call no. (call number) column |
| The Call no. column contains the internal call number of the relevant station. This number may contain a maximum of six digits. |
| When a fax or modem station is deleted (i.e., the call number and DID are deleted), the extension type must also be be reset to the default (standard). |
DID (direct inward dialing number) column |
| The DID number assigned to the corresponding extension is entered in this column. This number may contain a maximum of 11 digits. This is the call number used for DID and CorNet. |
| When a fax or modem station is deleted (i.e., the call number and DID are deleted), the extension type must also be be reset to the default (standard). |
|
|
Name column |
| The name assigned to the station is entered here. The name can also be entered via the Station view. More details on the name of a station can be found in the station view under Name. |
Status column |
| Can only be changed by physically reconfiguring the communication system. |
| The status of the relevant station port is displayed in the Status column. If a gray symbol or the * symbol appears in this column, the port (station) is inactive. If a green symbol appears in this column or if the field is empty, the port (station) is inactive. |
| Cordless base stations with SLUC cards are always shown as inactive, since this call number cannot be reached. |
| If a mobile phone is involved, the following status indicators are used: |
| |
|
Type column |
| Can only be changed by physically reconfiguring the communication system. |
| The type of telephone connected to the station port is automatically specified by the communication system. If a telephone is not connected, No Port is displayed in the column. If an analog telephone is connected, the column entry is "No Fe". |
| - | No Port, i.e. no telephone connected |
| - | No Fe, i.e. analog telephone connected |
| - | System telephone connected |
| - | S0 station |
Access column |
| Can only be changed by physically reconfiguring the communication system. |
| The name, number, slot of the station system board and the type of Workpoint Client (SYS=System, S0) are displayed here. This column also indicates whether the port is a master or a slave. |
| For an offline-configured database, there are no slave ports with HiPath 37xx. You can assign a slave port to a specific master port by double-clicking the Access field. The result is identical to connecting a slave terminal on the hardware side and then reading the CDB. If a slave port is assigned, you can remove it for both the master port and the slave port by double-clicking the Access field. |
CLIP column |
| If Configurable CLIP is activated, a valid DID number can be specified for each device here (see also Configurable CLIP under Flags). If no CLIP number was specified, the supplied Calling Partner Number is delivered (as before). |
| CLIP and LIN (Location Identification Number; only in the USA) are mutually exclusive. By default, LIN is activated for the USA and CLIP for all other countries. If CLIP is activated for the USA, LIN is automatically disabled. |
LIN column (Location Identification Number; USA only) |
| When emergency number E911 is set up, a valid DID (direct inward dialing) is entered for each telephone. This number identifies the location of the station from which the emergency call was made. There is no consistency test carried out for this. |
| LIN and CLIP are mutually exclusive (see also CLIP). |
Check button |
| Ensure that you have not assigned the same station number or DID number to two or more stations by pressing the Check button to initiate a check. If duplicates are found, an error message is displayed together with a list of the duplicates. You can then make appropriate corrections. |
| When assigning call numbers in the communication system to S0 stations, the closing digits of this number must be unique in relation to all internal call numbers of all other stations (for example: The S0 call number 9553193 conflicts with the station call number 193). |
| HiPath 3000/5000 V8, Manager E, Administrator Documentation, Issue 10 | up ![]() |
|
![]() |
||