8.19.11 |
Maintenance | V.24 Status |
| V.24 Status can be used to query the status of a V.24 interface on the central board or a terminal adapter of a sytem telephone. |
8.19.11.1 |
Area: Interface selection |
| Is used to select the wanted interface. A difference can be made between a V.24 interface on the central board or a terminal adapter of a sytem telephone. The V.24 interface can be selected via the V.24 port drop-down list. A terminal adapter can be selected by entering the station number of the sytem telephone, to which the terminal adapter has been connected. |
8.19.11.2 |
Area: Line status |
| After clicking on the Read data button, the states are displayed. |
| - | Line status = 1 means "Line active" |
| - | Line status = 0 means "Line inactive" |
| The individual lines are assigned as follows: |
| - | DTR: Communication system |
| - | DSR: Telephone |
| - | RTS: Communication system |
| - | CTS: Telephone |
| Two status examples are given in the following: |
| Example 1: Port open: |
| - | DTR: 1 |
| - | DSR: 0 |
| - | RTS: 1 |
| - | CTS: 0 |
| Example 2: HiPath 3000 Manager Online: |
| - | DTR: 1 |
| - | DSR: 1 |
| - | RTS: 1 |
| - | CTS: 1 |
8.19.11.3 |
Area: Monitoring V.24 |
| The Start and Stop buttons can be used to start or stop monitoring. In case of started monitoring, the incurred time and the number of sent/received bytes is displayed. |
| After monitoring has been stopped, the transferred bytes can be viewed by activating the buttons Hexadecimal, ASCII or Hex + ASCII. For this purpose, an external text editor (default is Wordpad) is started; this editor can also be used to store or print data. The desired editor can be configured via the File ass_150e.ini. |