15.3  

Configuration Notes 
 

Configuration of HiPath 5000 RSM  
The following entry must be made in the vsrv.ini file before starting the Feature server service:
[Global]
RSA=1

Configuration of a standby system  
When configuring a standby system (HiPath ComScendo Service or HiPath 3000) for the feature HiPath ComScendo Service Resilience, you must follow the procedure below:
 1.   Perform country initialization.
The system is bootstrapped. Previously saved data, such as, system speed dialing destinations and classes of service are deleted or reset to the basic settings (default).
 2.   Execute the licensing procedure.
HiPath ComScendo licenses are required for both the "regular" stations and the resilience stations.
 3.   Configure IP stations and resilience stations.
 4.   Delete the internal station numbers, DID numbers, and names of all resilience stations.

Configuration of a home system  
A resilience destination (= IP address of the standby system) must be defined for all resilience stations in the home system (HiPath 3000/5000 Manager E - Stationview - Workpoint Client).

Configuration of IP workpoint clients (resilience stations)  
Enter settings for the devices via the Web interface:
 1.   Enter the second gateway with the same number under "Administration/System/Gateway Settings".
 2.   Select "SRSR enabled" and "Automatic Switch back" under "Administration/System/SRSR Settings".
Change the parameters "Switch to home expiry timeout", "Switch to standby expiry timeout", and "TC_TEST expiry timeout" from the default value of 20 to "5".