11.5 |
Remote Administration of HiPath 3000 via PPP |
Definition |
| You can administer multiple HiPath 3000 systems from a central service center via PPP (point-to-point protocol). Each HiPath 3000 is addressed via its PSTN (public switching telephone network) interface. |
| You must enter a router call number (DID number) for every PSTN interface in the service center for external access to HiPath 3000. This number is not the station number previously used for administration via an integrated digital modem (B channel) or integrated analog modem (IMODC). |
|
| You can establish a connection between the service center and HiPath 3000 via the integrated digital modem (B channel) or the integrated analog modem (IMODC). The point-to-point protocol (PPP) is used in both cases for data exchange. |
|
| Figure 11-5 | Remote Administration of HiPath 3000 via PPP
|
| If the connection is established via callback, HiPath 3000 first of all denies a connection request from the service center (HiPath 3000/5000 Manager E). A callback is then set up to the service center's calling party number transferred via the PSTN connection's D channel. |
Model-Specific Data |
| |
| HiPath 3000/5000 V8, Feature Description, Issue 10 | up ![]() |
|
![]() |
||