12.3  

Call Duration Display on Telephone 
 
Implementing features, see also Manager E Call Duration Display on Telephone

Definition  
This feature shows the duration of external calls (incoming and outgoing) in the display as follows: HH:MM:SS. The system-wide option "Call timer display" must be activated for this.
The following applies up to and including V3.0 SMR-11: "Call timer display" option activated = default. The call charge display has priority.

 Call detail information from CO  
 "Call timer display" option  
 Shown in display  
 Yes  
 Activated  
 Call charges  
 Yes  
 Not activated  
 Call charges  
 No  
 Activated  
 call duration  
 No  
 Not activated  
 Dialed station number  
If this option is activated, the call duration is displayed for incoming calls. Otherwise the station number/name of the caller is displayed.  
The following applies to V3.0 SMR-12 or later: "Call timer display" option not activated = default. Display of the call duration has priority.

 Call detail information from CO  
 "Call timer display" option  
 Shown in display  
 Yes  
 Activated  
 call duration  
 Yes  
 Not activated  
 Call charges  
 No  
 Activated  
 call duration  
 No  
 Not activated  
 Dialed station number  
If this option is activated, the call duration is displayed for incoming calls. Otherwise the station number/name of the caller is displayed.  
The start of call detail recording for analog trunks is activated by means of a timer (five seconds after end of dialing). In the case of digital trunks, recording is started when the call is accepted (at "connect"). The dialed station number is displayed until this point. Numbers dialed in suffix-dialing mode are displayed for approximately five seconds. The call duration is displayed again. Once the call is ended, the display returns to idle status (current time and date).

Model-Specific Data  

 Subject  
 HiPath 3800  
 HiPath 3550  
 HiPath 3500  
 HiPath 3350  
 HiPath 3300  
Feature available in  
 x  
 x  
 x  
Hardware requirements  
 Telephones with display (optiPoint and OpenStage)  
Software requirements  
 V5.0 or later  
 V1.0 or later  
 V1.0 or later  

Dependencies/Restrictions  

 Subject  
 Dependency/Restriction  
S0 / cordless telephone  